ICSF: Deprecated parameters in installation options data set
Description
The ICSF installation options data set parameters COMPENC and PKDSCACHE were deprecated in FMID HCR7751 and parameters CKTAUTH, KEYAUTH, and TRACEENTRY were deprecated in FMID HCR77A1.
Table 1 provides more details about this migration action. Use this information to plan your changes to the system.
Element or feature: | Cryptographic Services. |
---|---|
When change was introduced: | ICSF FMIDs HCR7751 and HCR77A1. |
Applies to migration from: | All ICSF FMIDs before FMID HCR77B0. |
Timing: | Before the first IPL of z/OS V2R2. |
Is the migration action required? | Yes. |
Target system hardware requirements: | None. |
Target system software requirements: | None. |
Other system (coexistence or fallback) requirements: | None. |
Restrictions: | None. |
System impacts: | None. |
Related IBM Health Checker for z/OS check: | None. |
Steps to take
Edit the ICSF installation
options data set and remove all of the deprecated parameters.
Note: ICSF
starts with the deprecated parameters in the ICSF installation options
data set, but the parameters are ignored and message CSFO0212 is issued
for each deprecated parameter.
Reference information
For more information, see z/OS Cryptographic Services ICSF System Programmer's Guide.