HZSPRINT utility completion codes

The following list shows the completion codes returned by the HZSPRINT utility in system message IEF142I:

Completion code
Description
0
Success
400
No matches - the HZSPRINT utility could not match your request with checks.
401
HZSPRINT could not retrieve all messages from requested checks.
402
Some records were missing.
403
HZSPRINT could not write all the message buffers.
404
The log stream specified was empty.
801
An unknown keyword was encountered in the HZSPRINT parameter string.
802
Incorrect check owner specified. checkowner must be between 1-16 characters.
803
Incorrect check name specified. checkname must be between 1-32 characters.
804
Comma missing between checkowner and checkname in the HZSPRINT JCL.
805
Missing the closing parenthesis in CHECK(checkowner,checkname).
806
Incorrect log stream name specified.
811
No log stream was specified in the JCL.
812
The log stream specified was incorrect.
813
The check specified was bad.
814
No system name was specified in the SYSNAME parameter.
815
The system name specified in the SYSNAME parameter was incorrect.
816
The SYSNAME parameter is not allowed as specified - you can only specify SYSNAME with the LOGSTREAM parameter.
817
The syntax of the TIMERANGE value is invalid.
818
The TIMERANGE value is empty.
899
The HZSPRINT parameter string is too long.
1200
The HZSPRINT utility was not authorized to retrieve the requested information. For example, the XFACILIT class may not have been RACLISTed. Check the security definitions described in Setting up security for the HZSPRINT utility.
1201
The system could not open the specified SYSOUT data set. Check the SYSOUT data set requirements in Optionally set up the HZSPRINT utility.
1202
Unexpected logical record length on the specified SYSOUT data set.
1203
IBM Health Checker for z/OS is not active.
1204
HZSPRINT encountered an error with the log stream.
1205
The SYSOUT data set specified is not allocated.
1206
The specified SYSOUT data set is partitioned.
1601 -1604
Internal error. Contact the IBM® Support Center.