GP3174

Read syntax diagramSkip visual syntax diagram
   .-GP3174--=--NO----------------.   
>>-+------------------------------+----------------------------><
   |            .-NO------------. |   
   '-GP3174--=--+---------------+-'   
                '-group_address-'     

Specifies that a poll to an IBM® 3174 gateway controller can be a group poll for any station on the IBM 3174, including the IBM 3174 and the stations attached to the token ring.

group address indicates the hexadecimal group poll address and can be any two hexadecimal digits except X'00' and X'FF'.

You can change the value of GP3174 for SDLC non-switched PUs by dynamically adding the PUs using the DR ADD definition statement.