IST772I
UAC = uac [Q1 = qualifier1 Q2 = qualifier2 [Q3 = qualifier3] ]

Explanation

VTAM® issues this message as part of a message group. The first message in the group is IST755I. An alert has been received with a user action code (UAC) of uac. Any qualifiers that were contained in the alert will also be displayed (from 0–3 qualifiers).
Notes:
  1. The qualifier text is printed if qualifiers are received with the alert. For example:
    • If two qualifiers are attached to the alert, VTAM will not display the Q3 = qualifier3 text.
    • If no qualifiers are attached to the alert, VTAM will display only uac.
  2. If VTAM displays a UAC that is not listed below, VTAM does not recognize the UAC. See IBM 3720/3721 Communication Controller Daily Task and Problem Determination for information regarding UACs not listed in this manual.
A full description of the message based on the UAC follows:
UAC=01

Explanation: The maintenance and operator subsystem (MOSS) has a hardware error or there is a control program to MOSS communication error.

System Action: Processing continues.

Operator Response:
  • Do not attempt to IPL the 3720.
  • Perform a MOSS IML, set the Function Select switch of the 3720 operator panel to "NORMAL," and set the MOSS online.

    See the IBM 3720/3721 Communication Controller Operator’s Guide.

  • Use a MODIFY DUMP,TYPE=MOSS command to transfer the MOSS dump to the host for later printing.
  • If the problem persists, do not transfer the last MOSS dump. Save the system log for problem determination.

Programmer Response: Note the control program to MOSS interface status (Q1) and contact the IBM® hardware support center.

UAC=02

Explanation: The maintenance and operator subsystem (MOSS) has a recoverable error. The MOSS has been automatically reloaded.

System Action: Processing continues.

Operator Response:
  • Use a MODIFY DUMP,TYPE=MOSS command to transfer the MOSS dump to the host for later printing.
  • If the problem persists, do not transfer the last MOSS dump. Save the system log for problem determination.

Programmer Response: Note the reference code (Q1). Contact the IBM hardware support center.

UAC=03

Explanation: The maintenance and operator subsystem (MOSS) has a diskette drive or diskette adapter error.

System Action: Processing continues.

Operator Response: Save the system log for problem determination.

Programmer Response: Contact the IBM hardware support center.

UAC=04

Explanation: The maintenance and operator subsystem (MOSS) has a diskette media error.

System Action: Processing continues.

Operator Response: Save the system log for problem determination.

Programmer Response: Contact the IBM hardware support center.

UAC=05

Explanation: The maintenance and operator subsystem (MOSS) has a local console error.

System Action: Processing continues.

Operator Response: Save the system log for problem determination.

Programmer Response:
  • Verify that the local console operates in IBM 3101 mode. See the IBM 3720/3721 Communication Controller Problem Determination Guide.
  • Run a console test. See the console documentation.
  • Check the cable.
  • Run a console link test from the 3720 operator panel. See IBM 3720/3721 Communication Controller Daily Task and Problem Determination.
  • If no problem appears, note the reference code (Q2), and contact the IBM hardware support center.
UAC=06

Explanation: The maintenance and operator subsystem (MOSS) is offline because of maintenance mode.

System Action: Processing continues.

Operator Response: Save the system log for problem determination.

Programmer Response: Check for maintenance mode. If it is correct, set MOSS online. See the IBM 3720/3721 Communication Controller Operator's Guide.

UAC=07

Explanation: The communication controller has a hardware error. A communication controller IPL was re-executed.

System Action: Processing continues.

Operator Response:
  • Reactivate lines from host.
  • If the problem persists, save the system log for problem determination.

Programmer Response: Note the abend code (Q1) and the reference code (Q2). If you cannot determine the cause of the problem or need additional assistance, contact the IBM hardware support center.

UAC=08

Explanation: The communication controller has a software error. A communication controller IPL was re-executed.

System Action: Processing continues.

Operator Response:
  • Reactivate lines from host.
  • If the problem persists, save the system log for problem determination.
Programmer Response:
  • Ensure no mismatch exists between the hardware configuration and the control program generation (NCPCA, CA, HICHAN, LOCHAN). Valid for abend codes 912 and 915. Correct the generation problem, if any.
  • Dump the NCP and analyze the dump according to abend code (Q1).
  • If the problem does not appear to be a software problem, note the reference code (Q2) and contact the IBM hardware support center.
UAC=09

Explanation: A channel adapter error has occurred for channel adapter (Q1).

System Action: All sessions using routes over the failing adapter have been terminated, and appropriate recovery actions have been initiated.

Operator Response: Save the system log for problem determination.

Programmer Response:
  • Ensure the compatibility of communication controller channel-adapter parameters with the system (NSC address, ESC addresses, select out priority, burst length).
  • Note the reference code (Q2) and contact the IBM hardware support center.
UAC=11

Explanation: A scanner hardware error has occurred for scanner number Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response:
  • Reissue the IML command for the affected scanner from the MOSS console and reactivate the lines from the host.

    See the IBM 3720/3721 Communication Controller Operator’s Guide.

  • If the problem persists, save the system log for problem determination.

Programmer Response: Note the reference code (Q3) and contact the IBM hardware support center.

UAC=12

Explanation: A scanner hardware error has occurred for scanner number Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response:
  • Reissue the IML command for the affected scanner from the MOSS console and reactivate the lines from the host.

    See the IBM 3720/3721 Communication Controller Operator’s Guide.

  • Use the MODIFY DUMP,TYPE=CSP command to transfer the scanner dump to the host for later printing.
  • If the problem persists, do not transfer the last scanner dump. Save the system log for problem determination.

Programmer Response: Note the reference code (Q3) and contact the IBM hardware support center.

UAC=13

Explanation: A control program error or scanner error has occurred for scanner number Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response:
  • Reissue the IML command for the affected scanner from the MOSS console and reactivate the lines from the host.

    See the IBM 3720/3721 Communication Controller Operator’s Guide.

  • If the problem persists, save the system log for problem determination.
Programmer Response:
  • Check the addresses in control program generation. Correct generation in case of error.
  • Dump the NCP and analyze the dump.
  • If there does not appear to be a software problem, note the reference code (Q3) and contact the IBM hardware support center.
UAC=14

Explanation: A control program error or scanner error has occurred for scanner number Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response:
  • Reissue the IML command for the affected scanner from the MOSS console and reactivate the lines from the host.

    See the IBM 3720/3721 Communication Controller Operator’s Guide.

  • Use the MODIFY DUMP,TYPE=CSP command to transfer the scanner dump to the host for later printing.
  • If the problem persists, do not transfer the last scanner dump. Save the system log for problem determination.
Programmer Response:
  • Dump the NCP and analyze the dump.
  • If the problem does not appear to be a software problem, note the reference code (Q3) and contact the IBM hardware support center.
UAC=15

Explanation: A line error has occurred for line address Q2 on scanner number Q1.

System Action: The line is inoperative.

Operator Response:
  • Reactivate the line from the host.
  • If the problem persists, save the system log for problem determination.
Programmer Response:
  • According to the reference code (Q3), perform line problem determination with 3720 maintenance and operator subsystem (MOSS) facilities.

    See the IBM 3720/3721 Communication Controller Problem Determination Guide/

  • If the problem does not appear to be a software problem, note the reference code (Q3) and contact the IBM hardware support center.
UAC=16

Explanation: Re-execution of an automatic-scanner IML is in progress following a hardware error on scanner Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response: Wait for the re-execution of the automatic-scanner IML to complete. Another alert will indicate the IML completion. No action is required.

UAC=17

Explanation: Reexecution of an automatic-scanner IML is in progress following a control program error on scanner Q1. Lines in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response: Wait for the re-execution of the automatic-scanner IML to complete. Another alert will indicate the IML completion. No action is required.

UAC=18

Explanation: Re-execution of an automatic-scanner IML is complete following a scanner hardware error on scanner Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response:
  • Reactivate the lines from the host.
  • If the problem persists, save the system log for problem determination.

Programmer Response: Note the reference code (Q3) and contact the IBM hardware support center.

UAC=19

Explanation: Reexecution of an automatic-scanner IML is complete following a control program error or scanner error on scanner Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response:
  • Use the MODIFY DUMP,TYPE=CSP command to transfer the scanner dump to the host for later printing.
  • Reactivate the lines from the host.
  • If the problem persists, do not transfer the last scanner dump. Save the system log for problem determination.
Programmer Response:
  • Take an NCP dump (MODIFY DUMP,TYPE=NCP command) at the time of the re-execution of the scanner IML and analyze the dump.
  • If the problem does not appear to be a software problem, note the reference code (Q3) and contact the IBM hardware support center.
UAC=20

Explanation: A permanent hardware error has occurred for scanner Q1. Scanner re-execution of the IML has stopped. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response: Save the system log for problem determination.

Programmer Response: Note the reference code (Q3) and contact the IBM hardware support center.

UAC=21

Explanation: A permanent control program error or scanner error has occurred for scanner Q1. Reexecution of the scanner IML stopped. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response: Save the system log for problem determination.

Programmer Response:
  • Dump the NCP and analyze the dump.
  • If the problem does not appear to be a software problem, note the reference code (Q3) and contact the IBM hardware support center.
UAC=22

Explanation: Reexecution of the automatic-scanner IML failed because of a hardware error on scanner Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response: Save the system log for problem determination.

Programmer Response: Note the reference code (Q3) and contact the IBM hardware support center.

UAC=23

Explanation: Re-execution of the automatic-scanner IML failed because of a control program or scanner hardware error on scanner Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response: Save the system log for problem determination.

Programmer Response:
  • Dump the NCP and analyze the dump.
  • If the problem does not appear to be a software problem, note the reference code (Q3) and contact the IBM hardware support center.
UAC=24

Explanation: Re-execution of the automatic-scanner IML failed because of a hardware error or maintenance and operator subsystem (MOSS) error for scanner Q1. Lines whose addresses are in the range Q2 are inoperative.

System Action: All affected lines are inoperative.

Operator Response: Save the system log for problem determination.

Programmer Response: Note the reference code (Q3) and contact the IBM hardware support center.

UAC=25

Explanation: A maintenance and operator subsystem (MOSS) remote-console error occurred because of the line, modems, console or MOSS.

System Action: Processing continues.

Operator Response: Save the system log for problem determination.

Programmer Response:
  • Verify that the remote console, remote modem or local modem is powered on.
  • Verify the physical installation for the remote console, remote modem, local modem and cables.

    See the IBM 3720/3721 Communication Controller Problem Determination Guide.

  • Run modem tests. See the modem documentation.
  • Run a console test. See the console documentation.
  • Run a console link test from the 3720 operator panel.

    See IBM 3720/3721 Communication Controller Daily Task and Problem Determination.

  • If no problem appears, note the reference code (Q1) and contact the IBM hardware support center.
UAC=26

Explanation: A maintenance and operator subsystem (MOSS) remote-console error has occurred.

System Action: Processing continues.

Operator Response: Save the system log for problem determination.

Programmer Response:
  • Verify that the remote console operates in IBM 3101 mode.

    See IBM 3720/3721 Communication Controller System Integration.

  • Run a console test. See the console documentation.
  • If no problem appears, note the reference code (Q1) and contact the IBM hardware support center.
UAC=27

Explanation: An error occurred on the maintenance and operator subsystem (MOSS) disk or MOSS disk adapter.

System Action: Processing continues.

Operator Response: Save the system log for problem determination.

Programmer Response:
  • An IPL can be executed for the communication controller with the primary diskette on which the disk has been saved.

    See the IBM 3720/3721 Communication Controller Problem Determination Guide.

  • Note the reference code (Q1) and contact the IBM hardware support center.
UAC=30

Explanation: An error occurred on the maintenance and operator subsystem (MOSS) disk or MOSS disk adapter.

System Action: Processing continues.

Operator Response:
  • Do not IPL from the 3720 disk, or dump to the disk, until the disk is repaired.
  • The IPL can only be done by switching to diskette mode on the control panel and using the primary backup diskette on which the customized disk contents have been saved.

    See the 3720/3721 Communication Controller Operator’s Guide.

  • Save the system log for problem determination.

Programmer Response: Note the reference code (Q1) and contact the IBM hardware support center.

UAC=31

Explanation: A communication controller hardware error occurred. A communication controller IPL was re-executed.

System Action: Processing continues.

Operator Response:
  • Reactivate the lines from the host.
  • Use the MODIFY DUMP,TYPE=NCP,OPTION=TRANS command to transfer the communication controller dump to the host, then purge it from the 3720 disk.
  • If the problem persists, save the system log for problem determination.

Programmer Response: Note the abend code (Q1) and the reference code (Q2) and contact the IBM hardware support center.

UAC=32

Explanation: A communication controller software error occurred. An IPL has been re-executed for the communication controller.

System Action: Processing continues.

Operator Response:
  • Reactivate the lines from the host.
  • Transfer the communication controller dump to the host, then purge it from the 3720 disk.

    The dump does not have to be transferred to the host, but it should be purged from the 3720 disk. If the dump is not purged, the AUTODUMP/IPL sequence for a subsequent error will not occur.

  • If the problem persists, save the system log for problem determination.
Programmer Response:
  • Ensure there is no mismatch between the hardware configuration and the control program generation (NCPCA, CA, HICHAN, LOCHAN). Valid for abend codes 912 and 915. Correct the generation problem, if any.
  • Analyze the dump according to the abend code (Q1).
  • If there does not appear to be a software problem, note the reference code (Q2) and contact the IBM hardware support center.

Routing code

8

Descriptor code

5