This trace record is a continuation of the CFLS entry
when byte
X'06' in the CFLS entry indicates a READMULT, READLIST
or DELETEMULT request.
- Byte (hex)
- Contents
- 00–03
- Record ID: C"CFL2"
- 04
- Function code:
- X'08'REQUEST(READ_LIST) specified
- X'09'REQUEST(DELETE_MULT) specified
- X'0C'READ(READ_MULT) specified
- 05
- The value specified for the MODE parameter:
- X'01'MODE(SYNCSUSPEND) specified
- X'02'MODE(SYNCEXIT) specified
- X'03'MODE(AYSNCEXIT) specified
- 06–07
- The number of processed entries. If the number is greater than
65635, the number will be X'FFFF'.
- 08–0B
- The list number for which the data is being retrieved or deleted
- 0C–0F
- Access List Entry Token (ALET) of the data buffers in the buffer
object
- 10–1F
- For READLIST request, the 12-byte restart entry ID padded to the
right with zeros. For READMULT and DELETEMULT, the 16-byte restart
token.