0 | — | Equate Symbol: IwmRetCodeOk
Meaning: Successful completion.
Action:
None required. |
4 | — | Equate Symbol: IwmRetCodeWarning
Meaning: Successful completion, unusual conditions
noted. |
4 | xxxx041F | Equate Symbol: IwmRsnCodeExecEnvChanged
Meaning: The execution environment has changed while
the requested function is in progress.
Action:
None required. |
8 | — | Equate Symbol: IwmRetCodeInvocError
Meaning: Invalid invocation environment or parameters. |
8 | xxxx0801 | Equate Symbol: IwmRsnCodeSrbMode
Meaning: The caller is in SRB mode.
Action: Avoid requesting this function while in
SRB mode. |
8 | xxxx0803 | Equate Symbol: IwmRsnCodeDisabled
Meaning: Caller is disabled.
Action:
Avoid requesting this function while disabled. |
8 | xxxx0804 | Equate Symbol: IwmRsnCodeLocked
Meaning: The caller is locked.
Action:
Avoid requesting this function while locked. |
8 | xxxx080B | Equate Symbol: IwmRsnCodeBadPl
Meaning: Error accessing parameter list.
Action: Check for possible storage
overlay. Also check if you call this macro in 64-bit address mode.
Refer to the description of reason code xxxx089E for further information. |
8 | xxxx0810 | Equate Symbol: IwmRsnCodeEutFrr
Meaning: The caller has EUT FRR established.
Action: Avoid requesting this function with an EUT
FRR set. |
8 | xxxx0823 | Equate Symbol: IwmRsnCodeDatoff
Meaning: The caller invoked the service while DATOFF
Action: Avoid requesting this function in this environment. |
8 | xxxx0824 | Equate Symbol: IwmRsnCodeAmode24
Meaning: The caller invoked the service but was
in 24-bit addressing mode.
Action: Request
this function only when you are in 31-bit addressing mode. |
8 | xxxx0825 | Equate Symbol: IwmRsnCodeAscModeNotPrimary
Meaning: The caller invoked the service but was
not DAT on Primary ASC mode.
Action: Avoid
requesting this function in this environment. |
8 | xxxx0826 | Equate Symbol: IwmRsnCodeTaskTerm
Meaning: The caller invoked the service while task
termination is in progress for the task associated with the owner.
Action: Avoid requesting this function while task
termination is in progress. |
8 | xxxx0828 | Equate Symbol: IwmRsnCodeBadVersion
Meaning: Version number in parameter list is not
valid or version length field is not valid.
Action:
Check for possible storage overlay of the parameter list. |
8 | xxxx083A | Equate Symbol: IwmRsnCodeBadEnclave
Meaning: Enclave token does not pass verification.
Action: Check for possible storage overlay of the
enclave token, or asynchronous events which may have deleted the enclave. |
8 | xxxx0840 | Equate Symbol: IwmRsnCodeServiceNotEnabled
Meaning: The caller's space connection is not enabled
for this service
Action: Make sure that
SERVER_MANAGER=YES is specified on the IWMCONN request to enable this
service. |
8 | xxxx0841 | Equate Symbol: IwmRsnCodeXmemMode
Meaning: The caller is in cross-memory mode.
Action: Request this function only when you are
not in cross-memory mode. |
8 | xxxx0842 | Equate Symbol: IwmRsnCodeNoWLMConnect
Meaning: The caller's space is not connected to
WLM.
Action: Invoke the IWMCONN macro
before invoking this macro. |
8 | xxxx0850 | Equate Symbol: IwmRsnCodeBeginEnvOutstanding
Meaning: The caller is already operating under an
outstanding Begin environment.
Action:
Avoid requesting this function in this environment. |
8 | xxxx0851 | Equate Symbol: IwmRsnCodeSecEnvOutstanding
Meaning: The caller is already operating under an
outstanding security environment.
Action:
Avoid requesting this function while there is a task level security
environment outstanding. |
8 | xxxx0852 | Equate Symbol: IwmRsnCodeExecTokenNotCorrect
Meaning: The execution unit token does not identify
a previously selected work unit.
Action:
Verify that you have coded the WLMEUTKN parameter correctly. |
8 | xxxx0857 | Equate Symbol: IwmRsnCodeAlreadyInEnclave
Meaning: Current dispatchable work unit is already
in an enclave.
Action: Avoid requesting
this function while the caller is already in an enclave. |
8 | xxxx085A | Equate Symbol: IwmRsnCodeSelectedWorkActive
Meaning: The selected work element associated with
the input execution unit token is already in execution.
Action: You may have invoked IWMSTBGN from multiple
tasks in the server address space passing the same WLMEUTKN. Avoid
requesting this function in this environment. |
8 | xxxx089E | Equate Symbol: IwmRsnCodeServiceAModeMismatch
Meaning: The caller is in 64-bit address mode and
tried to invoke a service macro that is only enabled for a 31-bit
environment.
Action: Use the 64-bit enabled
service macro (IWM4STBG) or change the address mode of the caller
to 31-bit. |
C | — | Equate Symbol: IwmRetCodeEnvError
Meaning: Environmental error. |
C | xxxx0C17 | Equate Symbol: IwmRsnCodeSecEnvCreateFailed
Meaning: A user security environment cannot be created.
Action: Verify that the user ID is defined to RACF® or check the SAF installation
exit routine to enable the function. |
10 | — | Equate Symbol: IwmRetCodeCompError
Meaning: Component error.
Action:
Contact your system programmer. |