When you select the report classes option on the Definition menu, you go to the Create a Report Class panel. From there, you enter the report class name and description. The next time you choose the option from the Definition Menu, the application displays Report Class selection list.
To create a report class from the Modify Rules for Subsystem panel, enter a name in the report class field. Figure 1 shows a Modify Rules for the CICS® Subsystem panel. If you type in a name, for example CICSHOT, in the report class field, the application displays a Create Report Class pop-up panel. Figure 2 shows a Create a Report Class pop-up.
Subsystem-Type Xref Notes Options Help
Modify Rules for the Subsystem Type Row 1 to 6 of
Command ===> ____________________________________________ SCROLL ===> PAG
Subsystem Type . : CICS Fold qualifier names? Y (Y or N)
Description . . . IBM-defined USAA modified
Action codes: A=After C=Copy M=Move I=Insert rule
B=Before D=Delete row R=Repeat IS=Insert Sub-rule
-------Qualifier------------- -------Class--------
Action Type Name Start Service Report
DEFAULTS: PRDCICS CICSHOT_
____ 1 TN MSA* ___ PRDCICSM ________
____ 1 SI CICSTRN* ___ TRNCICS ________
****************************** BOTTOM OF DATA ******************************
Create a Report Class
An undefined report class was specified.
Press ENTER to define the class, or cancel to quit.
Report Class name : CICSHOT
Description . . . . ________________________________
When you press Enter, the report class is created, and is added to the report class selection list. You can type ? in the report class field on the Modify Rules for a Subsystem Type panel for a selection list of report classes.