SVC 102 (0A66)

AQCTL macro - is type 3, gets LOCAL and CMS locks.

Calls module IEDQEB, entry point IGC0010B.

GTF data is:
R15 and R0
No applicable data.
R1
Address of the parameter list.
PLIST
The parameter list is either one, two or three full words, the last of which has the high order bit on (X'80') to indicate the end. Byte zero of the first word contains the function code.
FUNCTION BYTE 0 BYTES 1-3
Opctl/network control X'84' Pointer to the APCIB.
Move in address space X'08' From pointer.
  X'00' To pointer.
  X'80' Pointer to the length.
Tpost to ready queue X'0C' Pointer to the RCB.
  X'00' Pointer to the RCB.
  X'80' Reserved.
  X'8C' Pointer to the RCB.
Get/Read X'90' Pointer to the ECB.
Put/Write X'94' Pointer to the ECB.
Point X'98' Pointer to the ECB.
CKREQ X'9C' Pointer to the ECB.
Post ECB. X'20' Pointer to the ECB.
  X'80' Pointer to the ASID.
Qreset. X'A4' Pointer to the ECB.