COUPLE SIGNAL DETAIL report

This report provides detailed information about XCF signalling and communication services. Information is presented for signalling using CTCs or using a coupling facility. This information includes:
The following command was issued to produce the SIGNAL report:
COMMAND===> COUPLE SIGNAL DETAIL GRPNAME(SYSIGW01)
                 * * * *   S I G N A L   D E T A I L   R E P O R T   * * * *

      XCF SIGNALLING DEFINITIONS FOR SYSTEM B7VBID86
      ----------------------------------------------
             Default Maxmsg:   3,000
        Default Retry Limit:      10
       Default Class Length:     956
 Transport  MaxMsg    Class
   Class      (K)     Length             Assigned Groups
 ---------  -------   ------  --------------------------------------
 DEFAULT      3,000      956  UNDESIG
     Outbound     Path  Maxmsg   Retry  Transport
 Signalling Path  Type    (K)    Limit    Class
 ---------------- ----  -------  -----  ---------
 08E0             CTC     3,000     10  DEFAULT
 08E1             CTC     3,000     10  DEFAULT
 IXC1             STR     3,000     10  DEFAULT
...

      Inbound     Path  Maxmsg   Retry
 Signalling Path  Type    (K)    Limit
 ---------------- ----  -------  -----
 0CE2             CTC     3,000     10
 0CE3             CTC     3,000     10
 IXC1             STR     3,000     10  DEFAULT
...


     XCF SIGNALLING CONNECTIVITY DETAIL FOR SYSTEM B7VBID86
      ------------------------------------------------------
 Detail of outbound connectivity from B7VBID86 to indicated systems:
  Target   System    Signalling
  System   Number   Connectivity  Connectivity Event         Time of Event
 -------- --------  ------------ --------------------  --------------------------
 B7VBID87 01000001      YES      Initialized           01/19/2009 08:38:33.379171
                                 Gained connectivity   01/19/2009 08:38:33.379174
                                 Signals transferred   01/19/2009 17:37:50.479915
 
History of outbound connectivity events on B7VBID86:
                                       System                Outbound
    Time Event Recorded      System   Number          Connectivity Event             Diag043  Diag042
 -------------------------- -------- -------- ---------------------------------      -------- --------
       There is no information to report.

 Detail of inbound connectivity to B7VBID86 from indicated systems:
  Source   System    Signalling
  System   Number   Connectivity  Connectivity Event         Time of Event
 -------- --------  ------------ --------------------  --------------------------
 B7VBID87 01000001      YES      Initialized           01/19/2009 08:38:33.378149
                                 Gained connectivity   01/19/2009 08:38:33.378152
                                 Signals transferred   01/19/2009 17:37:50.479915
 
History of inbound connectivity events on B7VBID86:
                                      System                Inbound
    Time Event Recorded      System   Number          Connectivity Event             Diag043  Diag042
 -------------------------- -------- -------- ---------------------------------      -------- --------
      There is no information to report.
 
Summary of Transport Class connectivity from B7VBID86 to indicated systems:
  Target  Transport #Oper     #No Path
  System    Class   Paths    Conditions
 -------- --------- ------  -------------
 B7VBID87 DEFAULT        3              0
      XCF SIGNALLING PATH DETAIL FOR SYSTEM B7VBID86
      ----------------------------------------------
 Signalling Path Definition for: CTC Device 08E0
                    System Name: B7VBID86
                      Direction: Outbound
                         Maxmsg:    3,000 K
                Transport Class:  DEFAULT
                    Retry Limit:       10
      Hardware
                      Unit Type: 3088 Model: 08
                    Device Type: 0000 Model: 00
      Current Resource Status
                Message length:        956
            Buffer space in use:          0 K
                  Signal format:      SP510
      Path Connection
                          State:   Operational
       Last established at time:    01/19/2009 08:38:33.381004
     Last established at signal:             0
                                 Outbound   Inbound
                                 --------   --------
                    System Name: B7VBID86   B7VBID87
                  System Number: 03000003   01000001
                     Connection: Local      Estblshd
          Desired Signal format: SP510      SP510
                         Device: 08E0       0CEF
      Signal Transfer
                         Status:          Idle
                #Sent when idle:        36,141
                #Sent when busy:           483
    First signal in working set:        49,222
     Last signal in working set:        49,221
                     #Completed:             0
                        #Failed:             0
                        #Active:             0
                         #To do:             0
 Data is incomplete, some queued signals not in dump

                    Signal#      Status    Token
                 -------------   ------   --------
      There is no information to report.
      Path Monitor
                         Status:          Idle
       Path operational at time:    01/19/2009 17:37:48.219701
         Duration of inactivity:             0 Seconds
          Last signal monitored:        49,218
          Last signal completed:        49,221
           #Path start/restarts:             2
                    Retry count:             0
      Path Requests
 
   Time Request Initiated     Request                Reason                   CC                     Diag073
 --------------------------   -------   -----------------------------------   --   ---------------------------------------------
 01/19/2009 08:38:33.358242   Start     Parmlib specification                 00   08180001 08012400 42000002 00000000 00000000
 01/19/2009 08:38:33.377593   Restart   Normal completion of start            00   08320220 -        -        -        -
      Path Request History
 
   Time Request Recorded      Request                 Reason                  Req#  Diag074  044  037  038  039  087
 --------------------------   -------   -----------------------------------   ----  -------- ---- ---  ---  ---  ---
      There is no information to report.
      Diagnostics
                         Diag030: 027388A0 00000005 00000000 00000001 00000001
                         Diag031: 00000004 00000000 A0420000 00040000
                         Diag032: 01
  IOSB: 02738E08
     +0000  FLA...... 40        FLB...... 00        FLC...... 2A        PROC..... 00        DVRID.... 16        FLD...... 38
     +0006  ASID..... 0006      PGAD..... FF4888A8  PKEY..... 00        COD...... 7F        OPT...... 94        OPT2..... C0
     +0010  UCB...... 00F1E8C8  CCWAD.... 0C84D870  DSTAT.... 00        SSTAT.... 00        CSWRC.... 0000
     +001C  SRB...... 02738E74  USE...... 00000000  IOPID.... 00000000  SCHC..... 4029      SNS...... 0000
     +002C  IPIB..... 00000000  PCHN..... 00000000  ERP...... 00000000  PCI...... FF485640  NRM...... FF488EA8
     +0040  ABN...... FF488EA8  DIE...... FF47C7F0  RST...... 0C84D868  VST...... 00041868  DSID..... 027388A0  LEVEL.... 01
     +0055  GPMSK.... 00        DCTI..... 0000      FMSK..... 00        CKEY..... 08        MDB...... 00        MDM...... 00
     +0060  CTC...... 00000000  SKM...... 00        SKBB..... 0000      SKCC..... 0000      SKH1..... 00        SKH2..... 00
     +006B  SKR...... 00
  UCBPRFIX: 00F1E8C0
     -0008  LOCK..... 00000000  IOQ...... 02540F80
  UCBOB: 00F1E8C8
     +0000  JBNR..... 00        FL5...... 00        ID....... FF        STAT..... 88        CHAN..... 08E0      FL1...... 08
     +0007  FLB...... 00        NXUCB.... 00F1E918  WGT...... 00        NAME..... 8E0       TBYT1.... 10        TBYT2.... 01
     +0012  DVCLS.... 41        UNTYP.... 00        FLC...... 00        EXTP..... F1E8A0    CTCAL.... 00000000  CTCF1.... 00
     +001D  RV042.... 000000    CTCWA.... 00000000
  UCBCMXT: 00F1E8A0
     +0000  ETI...... 19        STI...... 00        FL6...... 00        ATI...... 48        SNSCT.... 01        FLP1..... 01
     +0006  STLI..... 00        FL7...... 40        IEXT..... 0228B250  CHPRM.... 00        SATI..... 00
     +000E  ASID..... 0006      WTOID.... 000000    DDT...... 00FD7D00  CLEXT.... 00000000  DCTOF.... 0000      CSFLG.... 00
  UCBXPX: 0228B250
     +0000  RSTEM.... 00        MIHKY.... 07        MIHTI.... 40        HOTIO.... 40        IOQF..... 02540F80
     +0008  IOQL..... 02540F80
            Subchannel-Identification:
     +000C   CSS id                       00
     +000D   Iid/SSid                     01
     +000E   Number                       0026
     +0010  PMCW1.... 2888      MBI...... 0000      LPM...... 80        LPUM..... 80        PIM...... 80
     +0018  CHPID.... 54000000  00000000            LEVEL.... 01        IOSF1.... 00        IOTKY.... 00        MIHFG.... 00
     +0024  LVMSK.... 00000001
   Actual UCB Common segment address 00F1E8C8
   Device is installation-static
....

 Signalling Path Definition for: Structure IXC1
                    System Name: B7VBID86
 
                                  Pathout    Pathin
                                  --------   --------
                         Defined:      YES        YES
        Visible to other systems:      YES        YES
                          Maxmsg:    3,000 K    3,000 K
                 Transport Class:  DEFAULT        N/A
                     Retry Limit:       10         10

     Hardware                                               
                 Connection Name: SIGPATH_03000003          
                   Connect Token: IXCLO015 7F139100 00030001
              Connect Version ID: 00030001                  
            Structure Version ID: C39EB5A6 4D45DF8F         
          Maximum Structure Size: 10 M                      
           Actual Structure Size: 10 M                      
                    Number Lists: 64                        
 Maximum number signalling paths: 56                        
         Maximum number elements: 636                       
          Maximum number entries: 665                       
                    Vector Token: 0271D800 155B6A58 155B6A58
                   Vector Length: 32                        
  
                         List Signalling Paths
                  Other    Pathout from    Pathin to
                  System   B7VBID86        B7VBID86
                 --------  --------------  --------------
                 B7VBID87  Started         Started
      Path Connection
                      Acceptable: YES
                  Connect Status: Completed  IXLCONN RC/RSN: 00000000 00000000
               Disconnect Status: N/A
                      Rebuilding: NO
          Rebuild Connect Status: N/A
      Signal Transfer
 
                      Inbound List Transition:          01/19/2009 17:37:40.878427
                 Sending   Vectr
                  System   Index  Active   #Transitions   List#  Diag043  Diag084
                 --------  -----  ------  --------------  -----  -------- --------
                 B7VBID87      3      NO            2568      9  024BD0E0 7EF6D570
      Path Monitor
               Structure Status: Working
                 Pathout Status: Working
                  Pathin Status: Working
      Path Requests
 
 Dir    Time Request Initiated   Request               Reason                CC                   Diag073
 ---  -------------------------- ------- ----------------------------------- -- --------------------------------------------
 IN   01/19/2009 14:38:36.746008 Start   Operator request                    00 08690004 0E014B00 00000000 00000000 00000000
 OUT  01/19/2009 14:38:42.633309 Start   Operator request                    00 08690004 0E014B00 00000000 00000000 00000000
 STR  01/19/2009 14:38:43.376300 Restart Refresh control data from structure 00 087E0206 -        -        -        -
 
      Path Request History
 
 Dir   Time Request Recorded      Request                  Reason                   Req#  Diag074  044  037  038  039  087
 ---  --------------------------  -------     -----------------------------------   ----  -------- ---- ---  ---  ---  ---
      There is no information to report.
      Diagnostics
                         Diag030: 7EF6C768 00000014 00000000 00000000 00000001
                         Diag042: 7EF6C768

 Signalling Path Definition for: Structure IXC1             LIST#     8
                    System Name: B7VBID86
                      Direction: Outbound
                         Maxmsg:    3,000 K
                Transport Class:  DEFAULT
                    Retry Limit:       10
      Hardware
                  Connect Token: IXCLO015 7F139100 00030001
             Connect Version ID: 00030001
                     List limit:      320
                        Diag042: 7EF6C768
                        Diag084: 7EF6D590
      Current Resource Status
                 Message length:        956
            Buffer space in use:          0 K
                  Signal format:      SP510
      Path Connection
                          State:   Operational
       Last established at time:    01/19/2009 14:38:43.698393
     Last established at signal:             0
                                 Outbound   Inbound
                                 --------   --------
                    System Name: B7VBID86   B7VBID87
                  System Number: 03000003   01000001
                     Connection: Local      Estblshd
          Desired Signal format: SP510      SP510
                        Diag083: 0001       0001
                        Diag085: 01/19/2009 14:38:43.383935 03000003 00000000
                        Diag086: 03000003 00030001 01000001 00010001
                                 00000000 01400000 00010001 00000006
      Signal Transfer
                         Status:          Idle
                #Sent when idle:           305
                #Sent when busy:            15
    First signal in working set:        15,149
     Last signal in working set:        15,149
                     #Completed:             1
                        #Failed:             0
                        #Active:             0
                         #To do:             0
 
                    Signal#      Status    Token
                 -------------   ------   --------
      There is no information to report.
      Path Monitor
                         Status:          Idle
       Path operational at time:    01/19/2009 17:37:48.219701
         Duration of inactivity:             0 Seconds
          Last signal monitored:        15,149
          Last signal completed:        15,149
           #Path start/restarts:             4
                    Retry count:             0
      Path Requests
 
   Time Request Initiated     Request                Reason                   CC                     Diag073
 --------------------------   -------   -----------------------------------   --   ---------------------------------------------
 01/19/2009 14:38:42.643269   Start     System started to use structure       00   08180001 08710000 4A000008 00000000 00000000
 01/19/2009 14:38:43.383185   Restart   Reset parameters                      00   087C021B 00000140 00000281 00000002 01400000
      Path Request History
 
   Time Request Recorded      Request                 Reason                  Req#  Diag074  044  037  038  039  087
 --------------------------   -------   -----------------------------------   ----  -------- ---- ---  ---  ---  ---
      There is no information to report.
      Diagnostics
                         Diag030: 02378A90 00000005 00000000 00000001 00000001
                         Diag031: 00000004 00000000 A0400000 00040000
                         Diag032: 01

 Signalling Path Definition for: Structure IXC1             LIST#     9
                    System Name: B7VBID86
                      Direction:  Inbound
                         Maxmsg:    3,000 K
                Transport Class:      N/A
                    Retry Limit:       10
      Hardware
                  Connect Token: IXCLO015 7F139100 00030001
             Connect Version ID: 00030001
                     List limit:        0
                        Diag042: 7EF6C768
                        Diag084: 7EF6D5A0
      Current Resource Status
                 Message length:        956
            Buffer space in use:          0 K
                  Signal format:      SP510
      Path Connection
                          State:   Operational
       Last established at time:    01/19/2009 14:38:43.381254
     Last established at signal:             1
                                 Outbound   Inbound
                                 --------   --------
                    System Name: B7VBID87   B7VBID86
                  System Number: 01000001   03000003
                     Connection: Estblshd   Local
          Desired Signal format: SP510      SP510
                        Diag083: 0001       0001
                        Diag085: 01/19/2009 14:38:42.645802 03000003 00000000
                        Diag086: 01000001 00010001 03000003 00030001
                                 00000000 00000000 00010001 00000003
      Signal Transfer
                         Status:       Stalled
    First signal in working set:        15,101
     Last signal in working set:        15,104
                     #Completed:             1
                        #Failed:             0
                        #Active:             0
                         #To do:             0
 
                   Signal#      Status    Token
                 -------------   ------   --------
      There is no information to report.

      Path Monitor
                         Status:       Stalled
       Path operational at time:    01/19/2009 17:37:41.927091
         Duration of inactivity:             6 Seconds
          Last signal monitored:        15,102
          Last signal completed:        15,101
          #No buffer conditions:             0
           #Path start/restarts:             3
                    Retry count:             0
      Path Requests
 
   Time Request Initiated     Request                Reason                   CC                     Diag073
 --------------------------   -------   -----------------------------------   --   ---------------------------------------------
 01/19/2009 14:38:42.643280   Start     System started to use structure       00   08180001 08710000 4A000008 00000000 00000000
 01/19/2009 14:38:43.376275   Restart   Start converted to restart            00   08180001 087E1C20 5A400009 00000000 00000000
      Path Request History
 
   Time Request Recorded      Request                 Reason                  Req#  Diag074  044  037  038  039  087
 --------------------------   -------   -----------------------------------   ----  -------- ---- ---  ---  ---  ---
      There is no information to report.
      Timings for Recent Signal Transfers
                                                                                                               Signal
  Source Memtoken    TOD When MSGO Requested      Queue Time      Transfer Time        TOD When Arrived        Token
 -----------------  --------------------------  ---------------  ---------------  --------------------------  --------
 01000001 00000008  -                           -                -                01/19/2009 17:37:01.072607  00044800
 01000001 00000008  -                           -                -                01/19/2009 17:37:01.072678  000B3000
 01000001 00000008  -                           -                -                01/19/2009 17:37:01.072685  000BC000
 ...
      Diagnostics
                         Diag030: 024BD0E0 00000005 00000000 00000001 00000001
                         Diag031: 00000004 00000000 00400008 00040800
                         Diag032: 01
The next output shows the signalling path details that are presented for each outbound and inbound path. This information is omitted from the previous example.
      XCF DELIVERY STATUS SUMMARY FOR SIGNALS OUTBOUND FROM SYSTEM B7VBID86
      ---------------------------------------------------------------------
 Outbound Target   Target     Path    Last Signal   Last Signal   Last Signal
 CTC Path  CTC     System    Status    Accepted      Completed     Monitored
 -------- ------  --------  -------- ------------- ------------- -------------
 08E0     0CEF    B7VBID87  Idle            49,221        49,221        49,218
 08E1     0CEE    B7VBID87  Idle            90,056        90,056        90,055
     Outbound      Target     Path    Last Signal   Last Signal   Last Signal
     List Path     System    Status    Accepted      Completed     Monitored
 ---------------- --------  -------- ------------- ------------- -------------
 IXC1             B7VBID87  Idle            15,149        15,149        15,149
                   Target             Last InOrder #Pending Msgs  Last Pending
                   System               Msg Sent    Being Held     Msg Queued
                  ________           _____________ _____________ _____________
                  B7VBID87                   4,327             0             0
 
     XCF DELIVERY STATUS SUMMARY FOR SIGNALS INBOUND TO SYSTEM B7VBID86
      ------------------------------------------------------------------
0Inbound  Source   Source     Path    Last Signal  # Read   #Messages
 CTC Path  CTC     System    Status    Completed   Active  In Delivery
 -------- ------  --------  -------- ------------- ------ -------------
 0CEE     08E1    B7VBID87  Working         55,580      4             0
   Inbound List    Source     Path    Last Signal  # Read   #Messages
       Path        System    Status    Completed   Active  In Delivery
 ---------------- --------  -------- ------------- ------ -------------
 IXC1             B7VBID87  Stalled         15,101      0             0
                   Source             Last InOrder #Ordered Msgs
                   System             Msg Received  Being Held
                  ________           _____________ _____________
                  B7VBID87                   5,420             0

      XCF DELIVERY STATUS SUMMARY FOR SIGNALS LOCAL TO SYSTEM B7VBID86
      ----------------------------------------------------------------
 Transport   #Messages
   Class    In Delivery
 --------- -------------
      There is no information to report.
 
      XCF DELIVERY STATUS SUMMARY FOR MANAGED MESSAGES SENT BY SYSTEM B7VBID86
      ------------------------------------------------------------------------
      Broadcast, get response, and queued messages
                                  #Send  #Resp  Get  Msg
  Group    Source Member   #Targ   Pend   Pend  Rsp Status       Message ID        Message Anchor     Signal Token
 -------- ---------------- ------ ------ ------ --- ------ ---------------------- ----------------- -----------------
      There is no information to report.
 
      XCF DELIVERY STATUS DETAIL FOR MEMBERS ON SYSTEM B7VBID86
      ---------------------------------------------------------
      Detail of signal transfers for group:  SYSIGW01 member: IGWCLM01B7VBID86 memtoken: 03000001 00030004
  Source Memtoken    TOD When MSGO Requested      Queue Time      Transfer Time        TOD When Arrived       Diag043
 -----------------  --------------------------  ---------------  ---------------  --------------------------  --------
 01000001 00030002  01/19/2009 08:38:43.944234  00:00:00.000010  00:00:00.000057  01/19/2009 08:38:43.944302  0272A390
 02000001 00030003  01/19/2009 08:38:43.942389  00:00:00.000002  00:00:00.000051  01/19/2009 08:38:43.942442  02729390
 
    Detail of buffer sizes used by group:  SYSIGW01 member: IGWCLM01B7VBID86 memtoken: 03000001 00030004
0Size   Buffer   Signals for     Signals for
 Index  Length  Other Systems    Local System
 -----  ------  --------------  --------------
     0     956               2               0


      XCF BUFFER USAGE SUMMARY FOR SIGNALS OUTBOUND FROM SYSTEM B7VBID86
      ------------------------------------------------------------------
  Target  Transport Class   Msglen   Buff Space    Buff Space     #No Buffer
  System    Class   Length  In Use   In Use (K)    Allowed (K)    Conditions
 -------- --------- ------  ------  -------------  ------------- -------------
 B7VBID87 DEFAULT      956     956              8         12,000             0
 
     XCF BUFFER USAGE SUMMARY FOR SIGNALS INBOUND TO SYSTEM B7VBID86
      ---------------------------------------------------------------
  Source       Inbound     Path  Msglen  Buff Space  Buff Space   #No Buffer
  System  Signalling Path  Type  In Use  In Use (K)  Allowed (K)  Conditions
 -------- ---------------- ----  ------  ----------- ----------- -------------
 B7VBID87 0CEE             CTC      956           10       3,000             0
 B7VBID87 IXC1             LIST   4,028            0       3,000             0
 B7VBID91 0CEC             CTC    1,024            4       3,000             0
 B7VBID91 0CED             CTC    1,024            0       3,000             0 
      XCF BUFFER USAGE SUMMARY FOR SIGNALS LOCAL TO SYSTEM B7VBID86
      -------------------------------------------------------------
 Transport Class   Msglen  Buff Space  Buff Space   #No Buffer
   Class   Length  In Use  In Use (K)  Allowed (K)  Conditions
 --------- ------  ------  ----------- ----------- -------------
 DEFAULT      956     956            2       3,000             0
 
      XCF DETAIL OF MESSAGES FOR SYSTEM B7VBID86
      ------------------------------------------
      There is no information to report.

      XCF SIGNALLING WORK REQUEST SUMMARY FOR SYSTEM B7VBID86
      -------------------------------------------------------
                                      System
            Work Request               Name      Additional Work Request Data        Time Request Initiated   Diag041
 ----------------------------------- -------- -----------------------------------  -------------------------- --------
      There is no information to report.

      ACCOUNTING AND MEASUREMENT AREA HEADER FOR SYSTEM B7VBID86
      ----------------------------------------------------------
     +0000  TLEN..... 000026A4  #PTH..... 0000003C  LPTH..... 00001C20  OPTH..... 00000040  #MPE..... 00000000
     +0014  LMPE..... 00000000  OMPE..... 00001C60  #SYS..... 00000003  LSYS..... 000000E4  OSYS..... 00001C60
     +0028  #SD...... 00000032  LSD...... 00000960  OSD...... 00001D44  RSV...... 00000000  00000000  00000000
 
      ACCOUNTING AND MEASUREMENT SYSTEM ENTRIES FOR SYSTEM B7VBID86
      -------------------------------------------------------------
     +0000  TYP...... 04        RSV...... 00        LEN...... 004C      NME...... B7VBID87  DIR...... 40
     +000D  RSV...... 000000    PTH...... 00000003  BSY...... 00000000  NOP...... 00000000  MXB...... 00002EE0
     ...

      ACCOUNTING AND MEASUREMENT PATH ENTRIES FOR SYSTEM B7VBID86
      -----------------------------------------------------------
     +0000  TYPE..... 01        RSV...... 00        LENT..... 0078      NAME..... B7VBID86  DEV...... 0CED      DIR...... 80
     +0011  RSV...... 000000    ONME.....           ODEV.....           STAT..... 40        RSV...... 000000
     +0024  MRET..... 0000000A  #RET..... 00000000  #RST..... 00000005  MXMS..... 00000BB8  #SIG..... 00008BD5
    
      ACCOUNTING AND MEASUREMENT SRCDST ENTRIES FOR SYSTEM B7VBID86
      -------------------------------------------------------------
     +0000  TYPE..... 08        RSV...... 00        LENT..... 0030      GRP...... SYSXCF    MEM...... B7VBID87
     +001C  SCNT..... 00000033  RCNT..... 0000004C  MGRS..... 00000001  SNAM..... B7VBID87
     ...
 
      ACCOUNTING AND MEASUREMENT MSG PENDING ENTRIES FOR SYSTEM B7VBID86
      ------------------------------------------------------------------
      There is no information to report.
 IXC80305I SIGNAL DETAIL report encountered one or more validity check warnings.
 IXC80308I Run COUPLE SIGNAL EXCEPTION report.
 IXC80307I SIGNAL DETAIL report encountered one or more storage access failures, reported data may be incomplete.
 
                            * * * *  END OF COUPLE (CROSS-SYSTEM COUPLING FACILITY) REPORT  * * * *