ACR trace entries

An ACR trace entry represents failure of a processor and subsequent entry into the alternate CPU recovery component.

PR ASID TCB-ADDR  IDENT CD/D PSW----- ADDRESS- UNIQUE-1 UNIQUE-2 UNIQUE-3  PSACLHS-  PSALOCAL PASD SASD TIMESTAMP-RECORD  CP
                                               UNIQUE-4 UNIQUE-5 UNIQUE-6  PSACLHSE-

pr fail tcb-addr *ACR   cpu                    psaeepsw flg-crex psacstk-  psaclhs-  psalocal            timestamp------- CP
                                               psasuper psamodew           psaclhse- 
PR
pr: Identifier of the processor that produced the TTE.
ASID
fail: Home address space identifier (ASID) of the failing processor
TCB-ADDR
tcb-addr: Address of the task control block (TCB) for the current task for which the TTE was produced.
IDENT
The TTE identifier, as follows:
ACR
Alternate CPU recovery.
CD/D
cpu: The failing processor address from the PSACPUPA field of the PSA
PSW----- ADDRESS-
Blank
UNIQUE-1/UNIQUE-2/UNIQUE-3
UNIQUE-4/UNIQUE-5/UNIQUE-6
  • flg-crex: LCCACREX field of the logical configuration communication area (LCCA) for the failing processor.
  • psacstk-: PSACSTK field from the prefix save area (PSA) from the failing processor.
  • psaeepsw: PSAEEPSW field in the PSA. Bytes 1 and 2 contain the failing processor's address. Bytes 3 and 4 contain the external interruption code.
  • psamodew: PSAMODEW field in the PSA
  • psasuper: PSASUPER field in the PSA
PSACLHS-
psaclhs-: String for the current lock held, from the PSACLHS field of the PSA from the failing processor.
PSACLHSE-
psaclhse-: Extended string for the current lock held, from the PSACLHSE field of the PSA from the failing processor.
PSALOCAL
psalocal: Locally locked address space indicator, from the PSALOCAL field of the PSA from the failing processor.
PASD
pasd: Primary ASID (PASID) at trace entry.
SASD
sasd: Secondary ASID (SASID) at trace entry.
TIMESTAMP-RECORD
timestamp-------: Time-of-day (TOD) clock value when system trace created the trace entry. The value is in the same format as the time stamp on logrec data set records.
CP
The CP column contains 2 hex digits of the processor model dependent information, which is intended to identify the physical CP that made the trace entry. CP is only provided when formatting SYSTRACE under IPCS. CP is not provided for SYSUDUMP, SYSABEND, or SNAP.