Example of CTRACE DISPLAY PARAMETERS panel

The CTRACE DISPLAY PARAMETERS panel has the following format. When SYSID is specified, only those trace records that contain a sysplex system ID will be formatted and displayed. If SYSID is not specified, data from all the systems will be displayed.

--------- CTRACE DISPLAY PARAMETERS --------- Enter option
COMMAND ===>

System          ===>  (System name or blank
Component       ===>  SYSOMVS (Component name (required)
Subnames        ===>

GMT/LOCAL       ===>  G     (G or L, GMT is default)
Start/time      ===>        (mm/dd/yy,hh:mm:ss:dddddd or
Stop time       ===>         mm/dd/yy,hh.mm:ss.dddddd)
Limit           ===>  0      Exception ===>
Report type     ===>  SHORT  (SHort, SUmmary, Full, Tally)
User exit       ===>         (Exit program name)
Override source ===>
Options         ===>  SYSID(1)

To enter/verify required values, type any character
Entry IDs ===> Jobnames ===> ASIDs ===> OPTIONS ===> SUBS===>

CTRACE COMP(SYSOMVS) SHORT OPTIONS((SYSID(1)))

ENTER = update CTRACE definition.  END/PF3 = return to previous panel.
S = start CTRACE.  R = reset all fields.