The following table indicates the parameters you can specify in a CTnLOGxx parmlib member.
Parameters | Allowed on CTnLOGxx? |
---|---|
ON or OFF | Yes |
ASID | Yes |
JOBNAME | No |
BUFSIZE | Yes |
OPTIONS | Yes |
SUB | No |
PRESET | No |
LIKEHEAD | No |
WTR | Yes |
WTRSTART or WTRSTOP | Yes |
TRACEOPTS ON
BUFSIZE(16M)
OPTIONS('CONNECT,LOGSTRM,DATASET,SERIAL,MISC,LOCBUFF,RECOVERY')
These parameters turn on the default system logger tracing to ensure that specific trace options are included and to establish a default trace buffer of 16MB. These trace options are activated at System Logger initialization.
If the PARMLIB trace options specify OFF or when the operator turns the trace off, logger uses minimal tracing which consists only of unexpected events (i.e. COMPERR trace entries).