CTnLOGxx parmlib member

The following table indicates the parameters you can specify in a CTnLOGxx parmlib member.

Parameters Allowed on CTnLOGxx?
ON or OFF Yes
ASID Yes
JOBNAME No
BUFSIZE Yes
OPTIONS Yes
SUB No
PRESET No
LIKEHEAD No
WTR Yes
WTRSTART or WTRSTOP Yes
IBM® supplies the CTILOG00 parmlib member, which specifies the System Logger tracing activated at initialization. The contents of CTILOG00 as of V1.4 with OA07611 applied are:
TRACEOPTS ON
   BUFSIZE(16M)
	OPTIONS('CONNECT,LOGSTRM,Start of changeDATASETEnd of change,SERIAL,MISC,LOCBUFF,RECOVERY')

These parameters turn on the Start of changedefaultEnd of change system logger tracing to ensure that specific trace options are included and to establish a default trace buffer of 16MB. These trace options are activated at System Logger initialization.

Start of changeIf the PARMLIB trace options specify OFF or when the operator turns the trace off, logger uses minimal tracing which consists only of unexpected events (i.e. COMPERR trace entries).End of change