Explanation
A SETXCF START,REALLOCATE operator command was
issued to start the REALLOCATE process. Once started, the REALLOCATE
process will examine each allocated structure to determine the need
for adjustment by either activating a pending policy change and/or
changing the location of instance(s) allocated in CF(s). When the
structure needs to be adjusted, messages associated with the structure
rebuild process (IXC57nI and IXC52nI) and the deallocation process
(IXC579I) will be issued.
When the structure is not adjusted,
message IXC544I will be issued to provide an explanation.
In
the message text:
- strname
- Name of the structure for which information is recorded.
- WAS NOT ATTEMPTED BECAUSE
- The REALLOCATE process did not process the name structure for
the specified reason.
- reason
- One of the following:
- AN UNEXPECTED ERROR OCCURRED
- The REALLOCATE process cannot be performed because an unexpected
error occurred.
- STRUCTURE IS ALLOCATED IN PREFERRED CF
- The structure is allocated in preferred CF.
- OF A PENDING POLICY CHANGE TO DELETE THE STRUCTURE DEFINITION
- There is an administrative policy change pending. The pending
policy change is to delete the policy definition for the structure.
Since the change is to delete the structure from the CFRM active policy,
the structure rebuild process cannot be used to make the pending policy
changes active.
- OF A PENDING POLICY CHANGE TO SIZE/INITSIZE BUT ALTER NOT ALLOWED
- There is an administrative policy change pending. The pending
policy change includes a change to the SIZE or INITSIZE specifications.
Since at least one of the active or failed-persistent connections
to the structure does not allow alter processing AND system-managed
rebuild is required, the structure rebuild process cannot be used
to make the pending policy changes active.
- THERE IS NO CONNECTIVITY TO COUPLING FACILITY
- The CFRM active policy indicates that this system does not have
connectivity to the coupling facility where an instance of the structure
is allocated.
- OF AN UNEXPECTED ERROR WHEN BUILDING THE LIST OF ELIGIBLE CFS
- The REALLOCATE process encountered an unexpected error during
processing to build the list of coupling facilities where an instance
of the structure could be allocated. When this processing accessed
an allocated instance to determine the structure parameters, either
connectivity to the CF was lost or the command to the CF failed unexpectedly.
- A STRUCTURE REBUILD PROCESS IS IN PROGRESS
- The structure rebuild process is already in progress for the structure.
The structure rebuild process type could be either rebuild or duplexing
rebuild. For a duplexing rebuild, the in-progress processing could
be one of the following:
- The structure is duplexed. For a user-managed duplexing
rebuild, only one instance is allocated because the last user connected
to both instances disconnected in between another user's IXLCONN and
IXLCONN REBUILD requests.
- Process is in progress but has not reached duplexing established.
- Process has been stopped with KEEP=OLD.
- Process has been stopped with KEEP=NEW.
- THE STRUCTURE HAS FAILED
- The rebuild start request was rejected for one of the following
reasons:
- The request was to start a duplexing rebuild and
the structure has failed. Duplexing rebuild is not allowed when the
structure is in the failed state.
- The request would result in a system-managed rebuild. System-managed
rebuild is not allowed when the structure is in the failed state.
- THE STRUCTURE HAS NO ACTIVE CONNECTORS
- The request would have resulted in a user-managed process, but
the structure has no active connectors to participate in structure
rebuild processing.
- AT LEAST ONE CONNECTOR DOES NOT SUPPORT REBUILD
- At least one of the active connectors to the structure does not
support rebuild.
- NO SUITABLE COUPLING FACILITY FOR REBUILD WITH LOCATION=OTHER
- The rebuild start request was rejected because LOCATION=OTHER
was necessary and no other eligible coupling facility was found in
the preference list.
- NO COUPLING FACILITY PROVIDED BETTER OR EQUIVALENT CONNECTIVITY
- No other facility has better connectivity than the current one.
The rebuild would cause a degradation in connectivity as determined
by SFM system weights, if accepted.
- DUPLEXING REBUILD PREVENTED BY CONNECTOR(S)
- The structure does not support duplexing rebuild for one of the following
reasons:
- There are failed persistent connections that are unavailable until a
larger CFRM couple data set is made available.
- A user-managed duplexing rebuild could not be started because:
- User-managed duplexing rebuilds are not supported for the structure
type.
- At least one active or failed-persistent connection specified or
defaulted to IXLCONN ALLOWDUPREBLD=NO.
- A system-managed duplexing rebuild could not be started because:
- The structure has at least one active connector, and none of the
connectors (active or failed-persistent) specified IXLCONN ALLOWAUTO=YES
when connecting.
- THE STRUCTURE DOES NOT SUPPORT SYSTEM-MANAGED PROCESSES
- The structure does not support system-managed processes (for example,
rebuild) for one of the following reasons:
- The structure was not allocated in a coupling facility at or above
the minimum CFLEVEL required for the current process by a system supporting
system-managed processing.
- The structure has connections that have not been reconciled into
the CFRM active policy.
- Structure cleanup is in progress for the structure.
- NO SUITABLE COUPLING FACILITY IN PREFERENCE LIST
- The requested system-managed process cannot be initiated for one
or more of the following reasons:
- The preference list is empty.
- The preference list contains no other coupling facility at or
above the minimum CFLEVEL required for the current process.
- The structure already exists in the only suitable coupling facility.
The same coupling facility can only be selected as the target for
the system-managed rebuild if a CFRM policy change is pending, and
either:
- The policy changes does not involve updates to the SIZE or INITSIZE
values, or
- the policy change does involve updates to SIZE or INITSIZE and
all the structure connectors specified IXLCONN ALLOWALTER=YES.
- A potentially suitable coupling facility does not
permit structure allocation.
- CONNECTORS DO NOT SUPPORT SYSTEM-MANAGED PROCESSES
- The structure has at least one active connector, and at least
one of the connectors (active or failed-persistent) did not specify
IXLCONN ALLOWAUTO=YES when connecting.
- AT LEAST ONE CONNECTOR HAS LOST CONNECTIVITY
- The requested system-managed process (for example, rebuild) cannot
be initiated because one or more of the connectors to the target structure
has lost connectivity.
- THE CFRM CDS DOES NOT SUPPORT SYSTEM-MANAGED PROCESS
- The CFRM couple data set does not support the requested system-managed
process (for example, rebuild), because the CFRM couple data set was
not formatted at or above the minimum version for the system-managed
process requested. Use the DISPLAY XCF,COUPLE,TYPE=CFRM command to
determine the format of the CFRM couple data set. To support system-managed
rebuild the CFRM couple data set should be formatted specifying "ITEM
NAME(SMREBLD) NUMBER(1)". For system-managed duplexing rebuild, "ITEM
NAME(SMDUPLEX) NUMBER(1)" implicitly formats a CFRM couple data set
that supports both system-managed rebuild and system-managed duplexing
rebuild.
- A STRUCTURE WITH NO CONNECTORS HAS NEVER BEEN SYSTEM-MANAGED DUPLEXED
- A system-managed duplexing rebuild cannot be initiated because
there are no connections to the structure and the structure has not
previously been duplexed using system-managed processing.
- A CFRM ACTIVE POLICY DATA AREA COULD NOT BE OBTAINED
- The requested system-managed process (for example, rebuild) cannot
be initiated because the necessary CFRM active policy data area could
not be obtained.
- THE CFRM ACTIVE POLICY INDICATES REALLOCATE NOT ALLOWED
- The REALLOCATE process is bypassing the structure because ALLOWREALLOCATE(NO)
is specified in the CFRM active policy.
- STRUCTURE IS ALLOCATED IN PREFERRED CF AND POLICY CHANGE MADE
- The structure is allocated in the preferred CF and the pending
policy change was made. The policy change was made immediately because
the structure is allocated in the preferred CF according to the pending
policy and the pending policy did not affect the structure size.
- ALLOCATION OF REBUILD NEW STRUCTURE FOR DUPLEXING REBUILD NOT
FEASIBLE
- Allocation of the rebuild new structure instance in support of
a duplexing rebuild is not feasible. Message IXC574I will contain
additional diagnostic information.
- STRUCTURE OBJECTS IN STORAGE-CLASS MEMORY
- The request would have resulted in a duplexing rebuild, but a
duplexing rebuild could not be started because storage-class memory
is in use.
System action
The system continues the REALLOCATE process.
Operator response
Notify the system programmer.
System programmer response
Use the DISPLAY XCF,STR,STRNAME=strname operator
command to show the current state of the structure. Based on the current
state of the structure, use SETXCF and/or subsystem commands as required
to activate a pending policy change or adjust the structure location.
Source
Cross System Coupling Facility (SCXCF)
Module