Explanation
XCF has detected an inconsistency
in the couple data sets specified in COUPLExx. This system found the
couple data sets specified in COUPLExx are not the same couple data
sets last used by the sysplex for this data type. The system has
listed, via message IXC288I, those data sets last used by the sysplex
and also those specified in COUPLExx. The operator is to indicate
which is the correct set of couple data sets to be used for further
processing.
In the message text:
- typename
- The type of data contained in the data set.
When typename is
LOGR, see "LOGR
Couple Data Set Use Considerations" in z/OS MVS Setting Up a Sysplex for
more information.
- xx
- The suffix identifying the COUPLE parmlib member.
System action
System initialization processing stops until the
operator replies to message IXC289D.
Operator response
Choose one of the following replies:
- U
- To continue initialization with the primary and
alternate sysplex data sets that were last used by the sysplex, which
are not the same couple data sets specified in COUPLExx. This could
have been caused by the removal of a primary or an alternate couple
data set, or as the result of the addition of a new alternate couple
data set after the sysplex was IPLed. A normal re-IPL should choose
this option.
- C
- To continue initialization processing with the couple data sets
as specified in COUPLExx and not choose the sysplex couple data sets
that were last in use by the sysplex.
Attention:
This
option should only be chosen if the sysplex couple data sets specified
in the COUPLExx member are still valid since these are NOT the couple
data sets last in use by the sysplex.
If an incorrect reply is entered, the system issues
message IXC208I to notify the operator of the error. The system then
reissues message IXC289D.
System programmer response
This message resulted from a possibly
down level specification of the couple data sets in the COUPLExx parmlib
member. This could be caused by the removal of a primary or an alternate
couple data set or as the result of the addition of a new alternate
couple data set. Updating the COUPLExx parmlib member should eliminate
this message.
Source
Cross System Coupling Facility (SCXCF)
Module
Routing code
Descriptor code