This system detected an inconsistency in the couple data sets specified in COUPLExx. This system has resolved the inconsistency and has found a consistent primary and alternate couple data set. However, it does not appear that any active systems are using those data sets. Message IXC275I has been issued to identify the couple data sets specified by COUPLExx, as well as the resolved couple data sets that this system has determined to be consistent.
System initialization processing stops until the operator replies to message IXC269D.
Notify the system programmer.
This message indicates that the COUPLExx parmlib member specifies a sysplex couple data set configuration that is not the configuration currently or most recently used by the sysplex. This could be caused by the removal of a primary or an alternate or by the addition of a new alternate couple data set. Updating the COUPLExx parmlib member to describe the in-use or last-used couple data set configuration should eliminate this message.
Cross System Coupling Facility (SCXCF)
IXCL1DSI
1,2
2