XCF tried to initialize a data set as a primary or alternate couple data set, but found a problem with the data set.
If this is a primary couple data set, XCF will attempt to resolve the inconsistency by repairing the data from information contained on the alternate couple data set. If there is no alternate or if this error was on an alternate couple data set, then XCF will not be able to repair the inconsistency. If the inconsistency is not repaired, the couple data set is not placed into use. If the inconsistency is repaired, the couple data set is placed into use and initialization continues.
If the couple data set was placed into use then no further action is required. If the couple data set was not placed into use use then notify the system programmer and dump the couple data set. See the operator response to message IXC220W for the correct JCL to dump the couple data sets.
If the couple data set was placed into use then no further action is required. Otherwise IBM® service should be contacted. A dump of the the failing couple data set should be provided along with the information in the above message. One possible cause of the problem is a system reset of a system that had I/O active to the couple data set. Once all diagnostic information has been collected, the couple data set may be reformatted.
Cross System Coupling Facility (SCXCF)
IXCL1AAR
1,2,10
12