XCF could not open the data set indicated and will attempt to continue to IPL the system without it.
b
XCF issues message IXC255I, giving the details of the OPEN error which occurred for the specified data set and attempts to continue the IPL without it.
Contact the system programmer.
Determine why the open of the specified data set failed. If the name or volume serial of the data set is incorrect in the COUPLExx parmlib member, correct it before the next IPL. If the data set name and volser are valid, but the data set is on a volume that is inaccessible, format a new Sysplex couple data set on another volume, update the COUPLExx parmlib member, and use the SETXCF COUPLE,ACOUPLE command to add it to the current sysplex.
While the sysplex is running with only one Sysplex couple data set, it is exposed to errors on that device that could bring down the entire sysplex.
Cross System Coupling Facility (SCXCF)
1,2
2