IXC244E
XCF CANNOT USE {PRIMARY | ALTERNATE} SYSPLEX COUPLE DATA SET dsname, {ON VOLSER volser, | VOLSER N/A,} text

Explanation

XCF could not open the data set indicated and will attempt to continue to IPL the system without it.

b

In the message text:
dsname
The name of the couple data set.
volser
The DASD volume where the data set resides, if known. (It may be unknown when the master catalog is used to determine the volser, but the data set has not been cataloged.)
text
One of the following:
CONTINUING THE IPL USING SPECIFIED ALTERNATE AS PRIMARY
XCF is attempting to use the data set that was specified as the Alternate in the COUPLExx parmlib member as the Primary Sysplex couple data set, because the specified Primary could not be opened.
CONTINUING THE IPL WITHOUT AN ALTERNATE
XCF could not open the data set specified as the Alternate in the COUPLExx parmlib member, and is continuing without it.

System action

XCF issues message IXC255I, giving the details of the OPEN error which occurred for the specified data set and attempts to continue the IPL without it.

Operator response

Contact the system programmer.

System programmer response

Determine why the open of the specified data set failed. If the name or volume serial of the data set is incorrect in the COUPLExx parmlib member, correct it before the next IPL. If the data set name and volser are valid, but the data set is on a volume that is inaccessible, format a new Sysplex couple data set on another volume, update the COUPLExx parmlib member, and use the SETXCF COUPLE,ACOUPLE command to add it to the current sysplex.

While the sysplex is running with only one Sysplex couple data set, it is exposed to errors on that device that could bring down the entire sysplex.

Source

Cross System Coupling Facility (SCXCF)

Routing code

1,2

Descriptor code

2