IXG702I
NO TRACING IN EFFECT FOR SYSTEM LOGGER - SYSLOGR COMPONENT TRACE RESOURCE INITIALIZATION FAILED. DIAG: diag1

Explanation

System logger tried to initialize component tracing for SYSLOGR, but failed to obtain the required storage needed to store the component trace data. System logger is running without component tracing active.

In the message text:
diag1
Return code received from the STORAGE macro when system logger Initialization attempted to obtain storage for use by SYSLOGR component tracing.

System action

System logger initialization continues without component tracing for SYSLOGR.

Operator response

Notify system programmer.

System programmer response

See z/OS MVS Programming: Authorized Assembler Services Reference SET-WTO for the action to take when return code diag1 is issued by the STORAGE OBTAIN macro.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGBLF01

Routing code

1,2

Descriptor code

12