IXG216I
DISCONNECT COMPLETED FOR LOGSTREAM logstream DUE TO REQUIRED LOGGER RESOURCES NOT AVAILABLE. reason

Explanation

System logger was using a staging data set to duplex log data for a DASD only log stream, but an I/O error occurred and system logger could not allocate a new staging data set. System logger disconnects active connections to the log stream.

In the message text:
logstream
is the name of the disconnected log stream.
reason
One of the following:
STAGING DATA SET COULD NOT BE ALLOCATED AFTER I/O ERROR OCCURRED.
System logger was using a staging data set to duplex log data for a DASD only log stream. An I/O error occurred and a new staging data set could not be allocated.

System action

The active log stream connections have been disconnected.

Operator response

Notify the system programmer.

System programmer response

Check for I/O error and allocation error messages and correct the problem that led to the staging data set allocation error. After the problem has been resolved, have the application re-connect to the log stream.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGC4DIS

Routing code

11