Explanation
An error occurred during log stream recovery for
log stream logstream. Failed connections to the
log stream have not been recovered. There may be log stream data
that does not reside in the log stream DASD data sets and is not duplexed
by some combination of system logger local buffers, log stream staging
data sets, or coupling facility list structure.
In the message
text:
- logstream
- is the name of the log stream that has been recovered.
- strname
- is the name of the structure associated with the log stream.
- text
- is one of the following:
- STRUCTURE CONNECTION INFORMATION WAS NOT AVAILABLE
- Internal Error.
- NO STORAGE FOR STRUCTURE INFORMATION BUFFER
- Internal error.
- READ FOR LOGSTREAM RECORD FAILED
- Internal error.
- WRITER OFFLOAD CLEANUP FOR CONNECTOR FAILED
- Internal error.
- CONNECT TO LOGSTREAM NEEDING RECOVERY FAILED
- Internal error.
- READ FOR YOUNGEST LOGSTREAM BLOCK FAILED
- Internal error.
- NO STORAGE FOR IXLLIST BUFFER
- Internal error.
- READ FOR LIST CONTROLS FAILED
- Internal error.
- WRITE FOR LIST CONTROLS FAILED
- Internal error.
- READ FOR LOGSTREAM CONTROL RECORD FAILED
- Internal error.
- WRITE FOR LOGSTREAM CONTROL RECORD FAILED
- Internal error.
- READ/UPDATE LOGSTREAM RECORD FAILED
- Internal error.
- LOGSTREAM INVENTORY UPDATE FAILED
- Internal error.
- WRITE LOGSTREAM RECORD FAILED
- Internal error.
- DATA OFFLOAD FAILED
- Internal error.
- INITIATE DATA OFFLOAD FAILED
- Internal error.
- SYSTEM RECORD PROCESSING FAILED
- Internal error.
- ACTIVE SYSTEM INFORMATION WAS NOT AVAILABLE
- Internal error.
- COMPONENT SERIALIZATION ERROR
- Internal error.
- COMPONENT STORAGE ERROR
- Internal error
- READ FOR STRUCTURE RECORD FAILED
- Internal error
- SERIALIZATION NOT AVAILABLE
- Internal error
- diag1 diag2 diag3 diag4
- Is diagnostic information relating to the log stream recovery
failure. If diagnostic information is presented, it should be saved
and provided to the IBM® Software
Support Center.
System action
The log stream still has failed connections associated
with it. Recovery for the log stream will be attempted again on a
subsequent connect to the log stream or on a subsequent connect to
a log stream defined to the structure strname.
Operator response
Contact the system programmer.
System programmer response
Look for related messages that begin with IXL related to the structure referenced
in this message and try to resolve the problem. The diagnosis information
presented with this message should be saved. If this error persists,
report the problem to the IBM Software
Support Center.
User response
Programmer response
Source
Module
Routing code
Descriptor code