Explanation
The structure rebuild process has failed because
of the specified reason.
In the message text:
- strname
- is the new structure in the rebuild operation.
- NEW STRUCTURE TOO SMALL TO CONTAIN LOGSTREAM DATA
- The Structure Rebuild process has failed because the new structure
is not allocated with enough data entries to hold all the log stream
data from all the connectors participating in the structure rebuild.
Message
IXG106I is issued when the structure rebuild is stopped for this reason.
See message IXG106I for the correct action to take.
- IXLLIST FAILURE
- An IXLLIST list structure request failed during Local Buffer restore
processing.
A SYSLOGR Trace entry is produced and written to the
system logger trace buffer. A dump of the system logger trace buffer
should be requested to obtain diagnostic information that the IBM® support center will need to
diagnose the reason that caused the structure rebuild to stop.
- INTERNAL SYSTEM LOGGER FAILURE
- An internal system logger service failed preventing the structure
rebuild from continuing. The structure rebuild is stopped.
A SYSLOGR
trace entry is produced and written to the system logger trace buffer.
A dump of the system logger trace buffer should be requested to obtain
diagnostic information that the IBM support
center will need to diagnose the reason that caused the structure
rebuild to stop.
- CONNECTION TO THE NEW STRUCTURE FAILED
- A peer connector failed in attempting to connect to the new structure
during structure rebuild. Since not all original connectors have successfully
connected to the new structure, the rebuild is stopped.
A SYSLOGR
trace entry is produced and written to the system logger trace buffer.
A dump of the system logger trace buffer should be requested to obtain
diagnostic information that the IBM support
center will need to diagnose the reason that caused the structure
rebuild to stop.
- LOSS OF CONNECTIVITY TO THE NEW STRUCTURE
- The system has lost connectivity to the new structure and cannot
participate in the rebuild process. The structure rebuild is stopped
because the system that lost connectivity to the new structure was
not using staging data sets to duplex all of the log streams that
it was currently connected to at the time the structure rebuild started.
The structure rebuild is stopped to prevent a loss of data condition
for the log streams that this system is connected to.
The installation
should determine why the system lost connectivity to the new structure.
Correct the reason for the connectivity loss and reinitiate a structure
rebuild through the SETXCF START,REBUILD console command.
- IXLLIST OPERATION FAILED FOR NEW STRUCTURE
- An IXLLIST operation failed during structure rebuilding processing,
preventing structure rebuild from proceeding successfully.
A SYSLOGR
trace entry is produced and written to the system logger trace buffer.
A dump of the system logger trace buffer should be requested to obtain
diagnostic information that the IBM support
center will need to diagnose the reason that caused the structure
rebuild to stop.
- SYSTEM LOGGER STORAGE MANAGER FAILURE
- A request to the system logger storage manager to obtain resources
needed by structure rebuild processing had failed. The failure prevents
the structure rebuild from proceeding successfully.
A SYSLOGR trace
entry is produced and written to the system logger trace buffer. A
dump of the system logger trace buffer should be requested to obtain
diagnostic information that the IBM support
center will need to diagnose the reason that caused the structure
rebuild to stop.
- SYSTEM FAILURE
- A system has terminated while rebuild is in progress. The rebuild
is stopped to prevent possible loss of data.
The installation may
reinitiate a structure rebuild through the SETXCF START,REBUILD operator
command if another attempt to rebuild the structure is desired. Be
aware that if the original structure does not have any other systems
currently connected to the structure in the active state, reinitiating
a structure rebuild may result in a loss of data for log streams that
were connected to by the system that terminated if the log data written
by the terminated system was not duplexed by system logger staging
data sets.
To display detailed information about the indicated
structure, the following command may be issued from the operator console:
- D XCF,STRUCTURE,STRNAME=name
- SYSTEM LOGGER INVENTORY ERROR
- A request to update the system logger inventory records during
structure rebuild processing had failed. The failure prevents the
structure rebuild from proceeding successfully.
A SYSLOGR trace
entry is produced and written to the system logger trace buffer. A
dump of the system logger trace buffer should be requested to obtain
diagnostic information that the IBM support
center will need to diagnose the reason that caused the structure
rebuild to stop.
- NEW STRUCTURE HAS UNACCEPTABLE ATTRIBUTES
- The structure created for rebuild cannot be used because it is
not allocated with enough data entries to support the number of log
streams requested on the Inventory structure definition LOGSNUM keyword.
system
logger uses a small percentage of the allocated data entries in a
structure for internal processing. The most likely cause of this problem
is that the Coupling Facility which contains the newly allocated structure
does not have enough space available to allocate the structure at
the requested size.
Either more space needs to be made available
in the coupling facility, or the structure needs to be allocated in
a coupling facility that can accommodate it. More space can be made
available in a coupling facility by causing structures to be deallocated
from that facility, or by decreasing the amount of space reserved
for structure dumps. It may be necessary to modify the preference
list or the exclusion list defined in the CFRM policy to allow the
structure to be allocated in a more suitable coupling facility. Alternatively,
it may be necessary to make a new coupling facility available for
the sysplex to use.
- ERROR POPULATING NEW STRUCTURE WITH CONTROL LIST
- An internal failure occurred while refreshing control blocks and
populating the new structure with a control list.
A SYSLOGR trace
entry is produced and written to the system logger trace buffer. A
dump of the system logger trace buffer should be requested to obtain
diagnostic information that the IBM support
center will need to diagnose the reason that caused the structure
rebuild to stop.
- NEW STRUCTURE HAS INSUFFICIENT VECTOR LENGTH
- The structure created for rebuild cannot be used because the list
notification vector for the list structure is not large enough for
all the lists that need to be monitored for list transitions. There
was not enough storage available in the Hardware System Area (HSA)
for a larger vector. Enter a DISPLAY XCF,STR command to determine
which structures are in use. For each structure that is in use, enter
a DISPLAY,SCF,STR,STRNAME= inusestr, where inusestr is
the name of an in use structure, to determine which applications are
connected to the structure from this system. Consult the system programmer
as needed to determine whether to reduce the number of connector connected
to structures from the system stopped the structure rebuild, or to
modify the way in which the connectors are using the structure, or
to perform the steps needed to increase the amount of storage in the
Hardware System Area (HSA).
- LIST MONITORING REQUEST FOR THE NEW STRUCTURE FAILED
- A list monitoring request has failed for a list used by system
logger to manage the log streams defined to structure name.
The failure prevents the structure rebuild from proceeding successfully.
A
SYSLOGR trace entry is produced and written to the system logger trace
buffer. A dump of the system logger trace buffer should be requested
to obtain diagnostic information that the IBM support center will need to diagnose the
reason that caused the structure rebuild to stop.
- NEW STRUCTURE HAS INSUFFICIENT OPERATIONAL LEVEL
- The new structure resides in a coupling facility which does not
have a minimum operation level of 1. System logger requires a Coupling
Facility operation level of 1 or greater. It may be necessary to modify
the preference list or the exclusion list defined in the CFRM policy
to allow the structure to be allocated in a Coupling Facility with
the required operation level. Alternatively, it may be necessary to
make a new coupling facility available for the sysplex to use with
an operation level of at least 1.
- STAGING DATASET ERROR
- An error was encountered while repopulating the list structure
with log data from staging data sets.
A SYSLOGR trace entry is produced
and written to the system logger trace buffer. A dump of the system
logger trace buffer should be requested to obtain diagnostic information
that the IBM support center
will need to diagnose the reason that caused the structure rebuild
to stop.
- IXLLIST FAILURE
- IXLLIST FAILURE occurred during coupling facility repopulation
from staging data sets.
A SYSLOGR trace entry is produced and written
to the system logger trace buffer. A dump of the system logger trace
buffer should be requested to obtain diagnostic information that the IBM support center will need to
diagnose the reason that caused the structure rebuild to stop.
- REQUIRED OFFLOAD NOT COMPLETED
- A stalled or failed offload was encountered while the system attempted
to move CF structure resident data that was not duplexed for a log
stream defined to the structure being rebuilt. A SYSLOGR Component
Trace entry is produced and written to the system logger Component
Trace buffer. A dump of the system logger Component Trace buffer should
be requested to obtain diagnostic information that the IBM Support Center needs to diagnose the reason
that caused the structure rebuild to stop.
System action
A structure rebuild stop has been initiated and
the structure rebuild stop process begins.
Operator response
Notify the system programmer.
System programmer response
Take the action described for the
specific structure rebuild stop reason.
User response
Programmer response
Source