IXG056I
SYSTEM LOGGER ADDRESS SPACE HAS ENDEDtext

Explanation

The system logger address space has ended.

In the message text:
IXGLOGR IS AUTOMATICALLY RESTARTING.
IXGLOGR CANNOT BE AUTOMATICALLY RESTARTED.
OPERATOR ISSUED FORCE COMMAND. MANUAL RESTART REQUIRED.

System action

System logger services will be unavailable until the address space is restarted.

Operator response

Contact the system programmer.

System programmer response

System logger will attempt to automatically restart unless the system logger address space termination was due to operator command, or system logger has failed two auto restart attempts consecutively (an attempt at restarting is considered failed if logger is unable to initialize). If the system logger address space was not ended due to operator command, determine what caused the system logger address space to end by checking for error messages and by checking for any dumps created by the system logger address space. If the cause was not related to a configuration problem (such as if system logger lost access to the TYPE=LOGR couple data set) then contact the IBM® Support Center.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGR1EOT

Routing code

2,10

Descriptor code

4