The designated system has been removed from the sysplex. MVS™ is unable to initiate restarts of the elements defined in the designated restart group on another system for the indicated reason. The individual elements are identified in occurrences of message IXC802I which follow this message.
MVS deregisters the elements in the specified restart group that were running on the terminated system.
Notify the system programmer.
If the message text indicates a data set error, initiate appropriate problem analysis. If there are no eligible target systems, then determine if the restrictions imposed by the JES XCF group or the current automatic restart management policy are eliminating all SP5.2.0 systems as eligible target systems. Determine which systems are in the same JES XCF group as the system that terminated, or check the target system list specified in the automatic restart management policy. Check SYS1.LOGREC for a symptom record for this problem.