IXC735I
XCF ADMINISTRATIVE DATA UTILITY ENCOUNTERED AN ERROR: error_text

Explanation

The XCF administrative data utility program ended because of JCL errors.

In the message text:
error_text
A description of the error which occurred. error_text is one of the following:
VOLSER SPECIFIED WITHOUT DSN
The VOLSER keyword was specified on the TYPE control statement but the DSN keyword was missing.
UNABLE TO OPEN SYSIN
An error occurred when the system tried to open the SYSIN file. The SYSIN DD control statement may be missing.
I/O ERROR ON SYSIN
An I/O error occurred when the system attempted to read the SYSIN data set.
NO SYSIN CONTROL STATEMENTS
No control statements were provided in the SYSIN data set.
DATA TYPE CONTROL STATEMENT ERROR
One or more errors were encountered while processing the TYPE control statement.
DSN REQUIRED FOR THIS LEVEL OF MVS™
Only offline couple data sets can be updated on the current system level of MVS. The DSN keyword is required at this system level or rerun the utility on the level of MVS that supports ONLINE couple data sets.

System action

The administrative data utility program ends.

Operator response

Notify the system programmer.

System programmer response

Correct the JCL and rerun the program.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCM2APU, IXCM2PPI

Routing code

1, 2

Descriptor code

5