IXC725I
SYNTAX ERROR DETECTED IN LINE linenum. THE FOLLOWING WAS EXPECTED: expected_string BEFORE: position_string.

Explanation

The XCF Administrative Data Utility detected a syntax error. The expected_string was missing from a control statement.

In the message text:
linenum
The line number where the error was detected.
expected_string
The expected string.
position_string
This string identifies the position in the control statement prior to which the expected_string should be inserted.

System action

The system ignores the control statement and will continue to process subsequent statements.

Operator response

Notify the system programmer.

System programmer response

Correct the syntax error and rerun the utility.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCM2LEX

Routing code

1, 2

Descriptor code

5