IXC570I
SYSTEM-MANAGED process STARTED FOR STRUCTURE strname IN COUPLING FACILITY oldcfname PHYSICAL STRUCTURE VERSION: physicalver1 physicalver2 LOGICAL STRUCTURE VERSION: logicalver1 logicalver2 START REASON: reason [connreason] AUTO VERSION: procid1 procid2

Explanation

The system has accepted a request to start a system-managed process.

In the message text:

process
One of the following:
REBUILD
Initiation of a system-managed rebuild has been requested.
DUPLEXING REBUILD
Initiation of a system-managed duplexing rebuild has been requested.
strname
The name of the structure.
oldcfname
The coupling facility in which the original instance of the structure resides.
physicalver1
First half of the physical version number of the original instance of the structure.
physicalver2
Second half of the physical version number of the original instance of the structure.
logicalver1
First half of the logical structure version number.
logicalver2
Second half of the logical structure version number.
reason
One of the following:
CONNECTOR-SPECIFIED REASON
The user that initiated the process specified its own reason for starting it.
OPERATOR-INITIATED
The request that caused the process to be started indicated that the request was initiated by the operator.
POLICY-INITIATED
The request that caused the process to be started indicated that the request was initiated by the system based on the contents of the CFRM policy. Message IXC536I will contain additional information.
connreason
Connector-specified reason for starting the system-managed process. Present only when START REASON is CONNECTOR-SPECIFIED REASON. Consult the documentation for the application that initiated the process for the meaning of this value.
AUTO VERSION:
A unique value identifying the system-managed process being started. It can be used to correlate messages and XCF component trace records associated with the current system-managed process.
procid1
First half of the auto version.
procid2
Second half of the auto version.

System action

The system-managed process begins.

Operator response

Not applicable.

System programmer response

Not applicable.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCL2BLD

Routing code

2

Descriptor code

5