Explanation
The request to rebuild a structure is being stopped.
In
the message text:
- strname
- Name of the structure for which information is recorded.
- THE SPECIFIED POPULATECF HAS BEEN REMOVED FROM THE POLICY
- A policy change caused the PopulateCF coupling facility to be
removed from the active policy. No allocations can occur in that
facility, so the structure rebuild initiated to populate that facility
cannot be started.
- THE SPECIFIED POPULATECF IS BEING REMOVED FROM THE POLICY
- A policy change caused the PopulateCF coupling facility to be
marked as DELETE PENDING. The facility is in the process of being
removed from use, so the structure rebuild initiated to populate that
facility cannot be started.
- THE SPECIFIED POPULATECF HAS FAILED
- The coupling facility has failed. No allocations can occur in
the facility, so the structure rebuild initiated to populate that
facility cannot be started.
- AT LEAST ONE ACTIVE CONNECTION INDICATED THAT REBUILD IS NOT ALLOWED
- Rebuild not permitted because IXLCONN with ALLOWREBLD=NO was specified
by at least one active connection.
- NO ACTIVE CONNECTIONS TO THE STRUCTURE
- The rebuild request would have resulted in a user-managed rebuild,
but the structure has no active connectors to participate in rebuild.
- THE SPECIFIED POPULATECF IS NOT IN THE STRUCTURES PREFLIST
- A policy change caused the PopulateCF facility to be removed from
the structures preference list. Since the rebuild was started to
populate the specified facility, and this structure cannot be allocated
in that facility, the rebuild was not started.
- ANOTHER REBUILD REQUEST SUPERSEDED THE PENDING POPULATECF REQUEST
- While this structures rebuild was pending, another rebuild was
requested. The new rebuild request was processed immediately, and
the pending rebuild was cancelled.
- AN UNEXPECTED ERROR OCCURRED
- An unexpected error occurred during rebuild processing.
- NO COUPLING FACILITY PROVIDED BETTER CONNECTIVITY
- No other coupling facility has better connectivity
than the current one. The rebuild, which was initiated due to a loss
of connectivity, would cause a further degradation in connectivity
if accepted. The system evaluated the set of active connections that
lost connectivity to the current structure as compared with the set
of active connections that would not be able to connect to the rebuild
new structure. The system terminates structure rebuild processing
because the result of the rebuild would cause additional active connections
to lose connectivity.
- NO COUPLING FACILITY PROVIDED BETTER OR EQUIVALENT CONNECTIVITY
- No other coupling facility has better connectivity
than the current one. The rebuild would cause a degradation in connectivity
as determined by SFM system weights, if accepted.
- THE STRUCTURE IS BEING DEALLOCATED
- The last connector to the structure has disconnected, causing
the structure to be deallocated. It cannot be rebuilt for the PopulateCF
rebuild that is in progress.
- STRUCTURE HAS FAILED
- The rebuild start request was rejected because it would result
in a system-managed rebuild. System-managed rebuild is not allowed
when the structure is in the failed state.
- STRUCTURE DOES NOT SUPPORT SYSTEM-MANAGED PROCESSES
- The structure does not support system-managed processes (for example,
rebuild) for one of the following reasons:
- The structure was not allocated in a coupling facility at or above
the minimum CFLEVEL required for the current process by a system supporting
system-managed processing.
- The structure has connections that have not been reconciled into
the CFRM active policy.
- Structure cleanup is in progress for the structure.
- CONNECTORS DO NOT SUPPORT SYSTEM-MANAGED PROCESSES
- The structure has at least one active connector, and at least
one of the connectors (active or failed-persistent) did not specify
IXLCONN ALLOWAUTO=YES when connecting.
- POPULATECF COUPLING FACILITY NOT SUITABLE
- The requested system-managed process cannot be initiated because
the specified POPULATECF is not of a CFLEVEL at or above the minimum
required for the current process.
- START REASON INAPPROPRIATE FOR SYSTEM-MANAGED PROCESS
- An IXLREBLD REQUEST=START invocation would have resulted in system-managed
processing (for example, rebuild). The request specified a STARTREASON
of LOSSCONN or STRFAILURE, which are not valid reasons for the requested
process.
- AT LEAST ONE CONNECTOR HAS LOST CONNECTIVITY TO THE STRUCTURE
- The requested system-managed process (for example, rebuild) cannot
be initiated because one or more of the connectors to the target structure
has lost connectivity.
- CFRM COUPLE DATA SET DOES NOT SUPPORT SYSTEM-MANAGED PROCESS
- The CFRM couple data set does not support the requested
system-managed process (for example, rebuild), because the couple
data set was not formatted at or above the minimum version for the
system-managed process requested. Use the DISPLAY XCF,COUPLE,TYPE=CFRM
command to determine the format of the CFRM couple data set. To support
system-managed rebuild the CFRM couple data set should be formatted
specifying “ITEM NAME(SMREBUILD) NUMBER(1)”. For system-managed duplexing
rebuild, “ITEM NAME(SMDUPLEX) NUMBER(1)” should also be specified
when formatting a CFRM couple data set. Specifying “ITEM NAME(SMDUPLEX)
NUMBER(1)” implicitly formats a cfrm couple data set that supports
both system-managed rebuild and system-managed duplexing rebuild.
- STRUCTURE ALLOCATION NOT PERMITTED IN THE SPECIFIED COUPLING FACILITY
- A request to start a POPULATECF rebuild was attempted. Structure
allocation is not permitted in the specified coupling facility. The
request is not processed.
System action
Operator response
System programmer response
Source
Cross System Coupling Facility (SCXCF)
Module
IXCL2BLD, IXCL2FOR, IXCL2RSR
Routing code
Descriptor code