IXC542I
POPULATECF REBUILD FOR STRUCTURE strname NOT PROCESSED: text

Explanation

The request to rebuild a structure is being stopped.

In the message text:

strname
Name of the structure for which information is recorded.
THE SPECIFIED POPULATECF HAS BEEN REMOVED FROM THE POLICY
A policy change caused the PopulateCF coupling facility to be removed from the active policy. No allocations can occur in that facility, so the structure rebuild initiated to populate that facility cannot be started.
THE SPECIFIED POPULATECF IS BEING REMOVED FROM THE POLICY
A policy change caused the PopulateCF coupling facility to be marked as DELETE PENDING. The facility is in the process of being removed from use, so the structure rebuild initiated to populate that facility cannot be started.
THE SPECIFIED POPULATECF HAS FAILED
The coupling facility has failed. No allocations can occur in the facility, so the structure rebuild initiated to populate that facility cannot be started.
AT LEAST ONE ACTIVE CONNECTION INDICATED THAT REBUILD IS NOT ALLOWED
Rebuild not permitted because IXLCONN with ALLOWREBLD=NO was specified by at least one active connection.
NO ACTIVE CONNECTIONS TO THE STRUCTURE
The rebuild request would have resulted in a user-managed rebuild, but the structure has no active connectors to participate in rebuild.
THE SPECIFIED POPULATECF IS NOT IN THE STRUCTURES PREFLIST
A policy change caused the PopulateCF facility to be removed from the structures preference list. Since the rebuild was started to populate the specified facility, and this structure cannot be allocated in that facility, the rebuild was not started.
ANOTHER REBUILD REQUEST SUPERSEDED THE PENDING POPULATECF REQUEST
While this structures rebuild was pending, another rebuild was requested. The new rebuild request was processed immediately, and the pending rebuild was cancelled.
AN UNEXPECTED ERROR OCCURRED
An unexpected error occurred during rebuild processing.
NO COUPLING FACILITY PROVIDED BETTER CONNECTIVITY
No other coupling facility has better connectivity than the current one. The rebuild, which was initiated due to a loss of connectivity, would cause a further degradation in connectivity if accepted. The system evaluated the set of active connections that lost connectivity to the current structure as compared with the set of active connections that would not be able to connect to the rebuild new structure. The system terminates structure rebuild processing because the result of the rebuild would cause additional active connections to lose connectivity.
NO COUPLING FACILITY PROVIDED BETTER OR EQUIVALENT CONNECTIVITY
No other coupling facility has better connectivity than the current one. The rebuild would cause a degradation in connectivity as determined by SFM system weights, if accepted.
THE STRUCTURE IS BEING DEALLOCATED
The last connector to the structure has disconnected, causing the structure to be deallocated. It cannot be rebuilt for the PopulateCF rebuild that is in progress.
STRUCTURE HAS FAILED
The rebuild start request was rejected because it would result in a system-managed rebuild. System-managed rebuild is not allowed when the structure is in the failed state.
STRUCTURE DOES NOT SUPPORT SYSTEM-MANAGED PROCESSES
The structure does not support system-managed processes (for example, rebuild) for one of the following reasons:
  • The structure was not allocated in a coupling facility at or above the minimum CFLEVEL required for the current process by a system supporting system-managed processing.
  • The structure has connections that have not been reconciled into the CFRM active policy.
  • Structure cleanup is in progress for the structure.
CONNECTORS DO NOT SUPPORT SYSTEM-MANAGED PROCESSES
The structure has at least one active connector, and at least one of the connectors (active or failed-persistent) did not specify IXLCONN ALLOWAUTO=YES when connecting.
POPULATECF COUPLING FACILITY NOT SUITABLE
The requested system-managed process cannot be initiated because the specified POPULATECF is not of a CFLEVEL at or above the minimum required for the current process.
START REASON INAPPROPRIATE FOR SYSTEM-MANAGED PROCESS
An IXLREBLD REQUEST=START invocation would have resulted in system-managed processing (for example, rebuild). The request specified a STARTREASON of LOSSCONN or STRFAILURE, which are not valid reasons for the requested process.
AT LEAST ONE CONNECTOR HAS LOST CONNECTIVITY TO THE STRUCTURE
The requested system-managed process (for example, rebuild) cannot be initiated because one or more of the connectors to the target structure has lost connectivity.
CFRM COUPLE DATA SET DOES NOT SUPPORT SYSTEM-MANAGED PROCESS
The CFRM couple data set does not support the requested system-managed process (for example, rebuild), because the couple data set was not formatted at or above the minimum version for the system-managed process requested. Use the DISPLAY XCF,COUPLE,TYPE=CFRM command to determine the format of the CFRM couple data set. To support system-managed rebuild the CFRM couple data set should be formatted specifying “ITEM NAME(SMREBUILD) NUMBER(1)”. For system-managed duplexing rebuild, “ITEM NAME(SMDUPLEX) NUMBER(1)” should also be specified when formatting a CFRM couple data set. Specifying “ITEM NAME(SMDUPLEX) NUMBER(1)” implicitly formats a cfrm couple data set that supports both system-managed rebuild and system-managed duplexing rebuild.
STRUCTURE ALLOCATION NOT PERMITTED IN THE SPECIFIED COUPLING FACILITY
A request to start a POPULATECF rebuild was attempted. Structure allocation is not permitted in the specified coupling facility. The request is not processed.

System action

Not applicable.

Operator response

Not applicable.

System programmer response

Not applicable.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCL2BLD, IXCL2FOR, IXCL2RSR

Routing code

2

Descriptor code

5