IXC527I
THE REBUILD OF totalrebstr STRUCTURES IN COUPLING FACILITY cfname COULD NOT BE {STARTED|STOPPED}. SPECIFIC ERROR MESSAGES FOLLOW. THREAD: thread

Explanation

For START of structure rebuild processing, all structures in a coupling facility are examined to determine if the requested type (rebuild or duplexing rebuild) can be started for the structure. Message IXC528I will be issued for each structure that could not have structure rebuild processing started. For STOP of structure rebuild processing, all structures in a coupling facility with the requested type (rebuild or duplexing rebuild) of structure rebuild in progress are examined to determine if the process can be stopped. Message IXC528I will be issued for each structure that could not have structure rebuild processing stopped.

In the message text:

totalrebstr
Total number of structures for which the rebuild request could not be processed.
cfname
The name of the coupling facility.
STARTED
The request was to start structure rebuild processing.
STOPPED
The request was to stop in progess structure rebuild processing.
thread
Used to tie together messages and XCF component trace records for a particular coupling facility process.

System action

Structure rebuild processing continues or terminates for those structures for which the process was successfully started or stopped.

Operator response

Contact the system programmer for advice and assistance in determining whether to manually move the structures or cancelling the rest of the CFNAME level rebuild. Ensure the related IXC528I messages are preserved for the system programmer to use in determining next action.

System programmer response

Examine the related IXC528I messages for the correct next action. Note that depending on the application using the structure, the structure rebuild process may not be supported. Consult the application or subsystem documentation for recommendations.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCL2BLD

Routing code

10