IXC508A
REPLY K TO KEEP, D TO DELETE STRUCTURES FROM SYSPLEX plexname

Explanation

This is the prompt associated with message IXC523I.

In the message text:
plexname
Name of the sysplex from which structures were found.

System action

Structures are deleted or kept in the coupling facility based on the response.

Operator response

Notify the system programmer.

System programmer response

Determine if the structures from the other sysplex should be kept in the coupling facility or deleted from the coupling facility and respond. If D (delete) is specified, all structures from sysplex plexname will be deleted from the coupling facility identified in message IXC523I. If K (keep) is specified, the structures will remain in the coupling facility. To delete the structures at a later time, ownership of the coupling facility must be gained again to cause coupling facility cleanup process to reoccur.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCL2RC

Routing code

1,10

Descriptor code

2