IXC451I
INVALID SIGNAL PATH FROM SYSTEM osysname DEVICE outdev TO SYSTEM isysname DEVICE indev: text

Explanation

XCF detected an error in the configuration of sysplex signalling paths. The problem can be errors in either the COUPLExx parmlib members or the hardware configuration. This message appears on the system that defined the inbound side of the signalling path.

In the message text:
osysname
The system transmitting a message.
outdev
The device number for the outbound signalling path, coming from osysname.
isysname
The system receiving a message.
indev
The device number for the inbound signalling path, leading to isysname.
NOT SAME SYSPLEX
A signalling path was established between two systems that are not in the same sysplex. Signalling paths are only permitted between systems participating in the same sysplex.
COUPLE DATA SETS DIFFER
A signalling path was established between two systems that have the same sysplex name, but not the same couple data sets. The couple data sets must have matching names, volumes, and formatting time stamps.
CIRCULAR PATH
A signalling path leads back only to the same system. Circular signalling paths are not allowed.

System action

The system leaves the indicated signalling paths online and allocated to XCF. XCF does not use the signalling path until the problem is corrected. The system on the outbound side of the signalling path receives no information about this problem.

Operator response

Depending on the message text, do the following:
COUPLE DATA SETS DIFFER
NOT SAME SYSPLEX
Do one of the following:
  • If one of the systems is IPLing, try respecifying the COUPLExx parmlib member by responding to message IXC207A. If message IXC207A does not appear, then the system must be reIPLed in order to allow it to join the same sysplex.
  • If one of the systems is already active in the sysplex, enter either:
    • The DISPLAY XCF,SYSPLEX command to determine what sysplex name is being used by the active system.
    • The DISPLAY XCF,COUPLE command to determine what couple data sets are being used by the active system.
  • If the two systems involved are not supposed to be in the sysplex, no signalling path should connect them. Record the device numbers and system names identifier in the message and notify the system programmer. Enter a SETXCF STOP command on the active system where each device is defined to release resources associated with the signalling path.
CIRCULAR PATH
Enter a SETXCF STOP command on the system where the device is defined. Record the device numbers and system name identified in the message. Notify the system programmer.

System programmer response

Make sure that the COUPLExx parmlib member defines the correct signalling path or couple data set for the systems involved. Verify that the hardware configuration is correct and devices are correctly cabled.

If the problem persists, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCT1ME1

Routing code

1, 2

Descriptor code

12