IXC372I
VARY REJECTED, SYSTEM sysname text

Explanation

The VARY XCF command cannot be issued against system sysname for the reason described by text.

In the message text:
sysname
The name of the system specified on the VARY command for removal from the sysplex.
IS NOT PART OF THE SYSPLEX OR IS IPLING
The system specified on the VARY XCF command is not defined to the sysplex, or is IPLing into the sysplex.
DOES NOT SUPPORT THE REQUESTED AUTOIPL OPTIONS
The system specified on the VARY XCF command is not configured to support the AutoIPL options requested on the VARY XCF command.

System action

The system rejects the VARY XCF command.

Operator response

When the VARY XCF command is rejected because the system specified on the VARY XCF command is not defined to the sysplex or is IPLing into the sysplex, take the following steps:
  • Enter DISPLAY XCF,SYSPLEX,ALL or DISPLAY XCF,SYSPLEX,sysname to display the status of the systems in the sysplex. If the system specified on the VARY XCF command is not shown in the output from the DISPLAY XCF command, the system is not part of the sysplex and you do not need to issue the VARY XCF command.
When the VARY XCF command is rejected because the system specified on the VARY XCF command does not support the requested AutoIPL options, take the following steps:
  • Enter a DISPLAY DIAG command on system sysname to display the current options that have been set through DIAGxx parmlib members to determine if the system is configured to support AutoIPL.

System programmer response

A DIAGxx member containing AUTOIPL syntax must be processed successfully on system sysname to activate an AutoIPL policy. For more information about AUTOIPL policy statements and content, see the chapter that describes DIAGxx parmlib member processing in z/OS MVS Initialization and Tuning Reference.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCO1VCP

Routing code

1, 2

Descriptor code

5