System logger is alerting operations that the log stream primary storage consumption has exceeded the imminent threshold. This message was issued as per the WARNPRIMARY log stream specification and the MONITOR LSPRIMARY CONSUMPTIONALERT parmlib policy specification.
System logger continues accepting new IXGWRITEs for the log stream. Message IXG317E will be deleted when system logger detects after an offload activity the log stream usage drops 5% or more below the imminent imminentpct value.
If an offload is delayed due to a secondary storage inhibitor, system logger may issue messages IXG310I, IXG311I, IXG312E, and/or IXG271I, IXG272E. If the primary storage resource becomes full, system logger will no longer accept new IXGWRITEs for the log stream and message IXG318E will be issued.
Notify the System Programmer
D LOGGER,C,LSN=logstreamname,D
When the log stream duplexing option is listed as "DUPLEXING: STAGING DATA SET" in the display output, then also check the staging data set detail lines to see if the resource constraint stems from the data set being at or near full.
D XCF,STR,STRNAME=logger_structure
Check on the total and in use counts as well as the percentage full values for the CF structure entries and elements in the message IXC360I usage into portion of the display output.
Check for any conditions in the installation that may be preventing the offload from proceeding. Monitor for messages IXG310I, IXG311I, IXG312E, IXG271I, IXG272E or other offload related messages.
See 'Monitoring log stream interim storage consumption' in z/OS MVS Setting Up a Sysplex.
None.
None.
System logger (SCLOG)
IXGW1TSK
2
3