Start of change
IXG316E
STRUCTURE ENTRY CONSUMPTION OF curusage% IS AT OR ABOVE THE ENTRY THRESHOLD OF 90% FOR STRUCTURE strname

Explanation

Entry consumption for name system logger structure has passed the 90% entry threshold. This message was issued as per the WARNPRIMARY log stream specification and the MONITOR LSPRIMARY CONSUMPTIONALERT parmlib policy specification.

In the message text:
curusage
Is the current percentage of CF structure entries in-use by system logger.
strname
Is the name of the structure which has reached the 90% entry threshold.

System action

System logger initiates an offload for all log streams defined to structure strname. System logger continues accepting new IXGWRITEs for the log stream. Message IXG316E will be deleted when system logger detects after an offload activity the entry usage falls to 85% or a lower value.

Operator response

Notify the System Programmer

System programmer response

Check for any conditions in the installation that may be preventing an offload from proceeding.

Issue a D XCF,STR,STRNAME=strname to view the current usage information for structure strname. Check for signs that structure strname is not properly tuned if there are many elements available, but the structure is constrained on entries.

Monitor for messages IXG310I, IXG311I, IXG312E, IXG271I, IXG272E or other offload related messages for log streams defined to the structure. See 'Monitoring log stream interim storage consumption' in z/OS MVS Setting Up a Sysplex.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGW1TSK

Routing code

2

Descriptor code

3

End of change