text OF STRUCTURE
strname[
AUTO VERSION:
procid1 procid2]
[
stralloc STRUCTURE ALLOCATED IN COUPLING FACILITY:
cfname1 cfname2]
[polinfo]text2 Explanation
For the specified structure, either
the REALLOCATE process was evaluating the structure or a structure
rebuild process of the specified type was being started or in progress.
This message provides further information about the evaluation, feasibility,
or allocation decision based on the coupling facilities in the structure's
preference list.
When sorting the CF eligibility
queue for all system-managed rebuild processing and reallocate processing,
SFM weight is given priority over other attributes. For a structure
without any active connectors, the SFM weight of each coupling facility
is the sum of the SFM weights of all systems connected to that coupling
facility. For a structure with active connectors, only systems with
active connectors are used to determine the SFM weight of the coupling
facility. All systems are considered to have equal SFM weight if no
SFM policy is active.
Note that for a POPULATECF rebuild request,
only the POPULATECF is considered as a possible location for the new
instance of the structure, and only that coupling facility will be
listed.
In the message text:
- text
- One of the following:
- ALLOCATION INFORMATION FOR SYSTEM-MANAGED REBUILD
- A system-managed rebuild was in progress for the specified structure.
This system attempted to allocate the rebuild new instance of the
structure, and succeeded or failed as described by messageIXC578I
and IXC582I, or IXC573I, respectively.
- ALLOCATION INFORMATION FOR SYSTEM-MANAGED DUPLEXING REBUILD
- A system-managed duplexing rebuild was in progress for the specified
structure. This system attempted to allocate the rebuild new instance
of the structure, and succeeded or failed as described by message IXC578I and IXC582I, or IXC573I, respectively.
- ALLOCATION FEASIBILITY INFORMATION FOR DUPLEXING REBUILD
- A request to start a user-managed duplexing rebuild
for the specified structure was being processed. This system determined
that allocation of the rebuild new structure instance was not feasible.
- EVALUATION INFORMATION FOR REALLOCATE PROCESSING
- The REALLOCATE process is evaluating an allocated structure using
the XCF allocation criteria to analyze the coupling facilities in
the preferred list. The preferred coupling facilities are used in
determining whether the location of the structure instance(s) should
be adjusted by using structure rebuild processing.
- strname
- Name of the structure for which information is recorded.
- AUTO VERSION:
- A unique value identifying the system-managed process in progress.
It can be used to correlate messages and XCF component trace records
associated with the current system-managed process.
- procid1
- First half of the auto version.
- procid2
- Second half of the auto version.
- stralloc
- One of the following:
- SIMPLEX
- The structure is simplex with one instance allocated.
- DUPLEXED
- The structure is duplexed with two instances allocated.
- cfname1
- Name of coupling facility from the CFRM active policy. For a simplex
structure, this is the name of the coupling facility containing the
only instance. For a duplexed structure, this is the name of the coupling
facility containing the old instance.
- cfname2
- Name of coupling facility from the CFRM active policy. For a simplex
structure, this is blank. For a duplexed structure, this is the name
of the coupling facility containing the new instance.
- polinfo
- One of the following:
- ACTIVE POLICY INFORMATION USED.
- The current active policy definition was used.
- PENDING POLICY INFORMATION USED.
- The pending policy definition was used.
- ACTIVE POLICY INFORMATION USED BUT EXCLUSION LIST WAS IGNORED.
- The current active policy definition for the structure was used
but the exclusion list was ignored.
- PENDING POLICY INFORMATION USED BUT EXCLUSION LIST WAS IGNORED.
- The pending policy definition for the structure was used but the
exclusion list was ignored.
- text2
CFNAME STATUS/FAILURE REASON
--------- ------------------------------------------------------
cfname status
[INFO110: data1 data2 data3]
[data 4 data5 data6]
[subreason]
- cfname
- Name of the coupling facility for which information is recorded.
- status
- One of the following:
- STRUCTURE ALLOCATED
- Structure was successfully allocated in the specified coupling
facility.
- NO CONNECTIVITY
- The CFRM active policy indicates that this system does not have
connectivity to the specified coupling facility. This message may
be accompanied by message IXC575I, indicating that another system
will attempt to allocate the structure. That system will also issue
message IXC574I to record the results of its allocation attempt. If
no system succeeded in allocating the structure, re-establish physical
connectivity to the coupling facility and re-initiate the system-managed
process for which allocation was attempted.
- COUPLING FACILITY NOT IN ACTIVE POLICY
- The coupling facility is not listed in the active policy so it
is not viable until the policy is changed.
- CONNECTIVITY LOST
- An attempt to allocate the structure in this coupling facility
was unsuccessful because connectivity to the coupling facility has
been lost. If structure allocation failed, establish physical connectivity
to the coupling facility and reinitiate the system-managed process
for which allocation was attempted.
- COUPLING FACILITY FAILURE
- The coupling facility has failed.
- STRUCTURE FAILURE
- The new instance of the structure failed during the allocation
process.
- PARAMETER ERROR
- The requested structure attributes are inconsistent with the model-dependent
attributes of the coupling facility. Contact IBM® service.
- INVALID STRUCTURE SIZE
- The target structure size was too small to allocate the structure
with the attributes specified. If the allocation failed, the CONAFACILITYMINREQSIZE
field of the ConaFacilityArray section of the LOGREC symptom record
provided with message IXC573I is set to the minimum size
of the structure if it were to be allocated in this coupling
facility with the requested attributes. The amount
of storage required by the structure also increases as a function
of the CFRM policy SCMMAXSIZE specification. Requesting a large amount
of storage-class memory can significantly increase the minimum structure
size. Increase the maximum structure size specified in the CFRM
policy.
- ALLOCATION NOT PERMITTED
- New structures cannot be allocated in the coupling facility according
to the CFRM active policy. One or more subreason message
lines explain why the structure cannot be allocated in the specified
coupling facility.
- XCF COMPONENT ERROR
- An XCF component error has occurred. Contact IBM service.
- UNKNOWN HARDWARE ERROR
- An unknown hardware error has occurred. Contact IBM service.
- INSUFFICIENT SPACE
- There was not sufficient space in the coupling facility to allocate
the structure. If structure allocation failed, examine the ConaFacilityArray
section of the LOGREC symptom record provided with message IXC573I.
CONAFACILITYMINREQSIZE is set to the minimum size
of the structure if it were to be allocated in this coupling
facility with the requested attributes. The amount
of storage required by the structure also increases as a function
of the CFRM policy SCMMAXSIZE specification. Requesting a large amount
of storage-class memory can significantly increase the minimum structure
size. Some amount of additional storage, over and above the structure
size, may also be required to support storage-class memory. Make
sure there is a coupling facility in the structure's preference list
with sufficient space.
- RESTRICTED BY REBUILD OTHER
- LOCATION=OTHER was specified on the rebuild request. Since the
original structure was allocated in this coupling facility, the system
did not use this coupling facility when trying to allocate the new
structure for rebuild. If the structure allocation failed, make sure
there is another suitable coupling facility in the structure's preference
list.
- INSUFFICIENT CONNECTIVITY
- The coupling facility does not provide connectivity at least equivalent
to the connectivity provided by the coupling facility in which the
original structure resided.
- PREFERRED CF ALREADY SELECTED
The system did not select the coupling facility
because a preferable coupling facility was already selected. When
the coupling facility status is PREFERRED CF ALREADY SELECTED or PREFERRED
CF 2, the message displays one of the following lines that gives the
primary reason why this coupling facility was placed lower than the
previous one in the eligibility queue. Because of how different requirements
are weighted, this information does not imply that all coupling facilities
higher in the eligibility queue meet the requirement:
- CONNECTIVITY REQUIREMENT MET BY PREFERRED CF
- At least one connector to the current (old) structure does not
have connectivity to this coupling facility, or
the reporting system does not have connectivity, and there is
at least one coupling facility to which all connectors do have connectivity.
- CFLEVEL REQUIREMENT MET BY PREFERRED CF
- Another coupling facility was found with a more appropriate CF
level.
- FAILURE ISOLATION FOR DUPLEXING MET BY PREFERRED CF
- This coupling facility is not failure isolated for duplexing,
this is a duplexing rebuild, and at least one coupling facility exists
that is failure-isolated for duplexing.
- SPACE AVAILABLE FOR REQUESTED SIZE IN PREFERRED CF
- This coupling facility does not have enough free space to meet
the requested structure size, and at least one coupling facility exists
that does have enough free space to allocate the structure at the
requested size.
- SPACE AVAILABLE FOR MINIMUM SIZE IN PREFERRED CF
- This coupling facility does not have enough free space to meet
the minimum required structure size to allocate the new structure
instance based on the current object counts, and at least one coupling
facility exists that does have enough free space to allocate the structure
at the minimum size.
- SPACE AVAILABLE FOR CHANGED DATA IN PREFERRED CF
- This coupling facility does not have enough free space to meet
the minimum required structure size to allocate the new structure
instance based on the current in-use and changed object counts, and
at least one coupling facility exists that does have enough free space
to allocate the structure but with changed data only.
- MORE SPACE AVAILABLE IN PREFERRED CF
- This coupling facility does not have enough free space to allocate
the structure at the requested size, and at least one coupling facility
exists that also does not have enough free space but does have more
space than this one.
- STORAGE-CLASS MEMORY REQUIREMENT MET BY PREFERRED CF
- This coupling facility does not have enough free storage-class
memory to allocate the structure based on the current object counts,
and there is at least one coupling facility that does have sufficient
storage-class memory. Note that storage-class memory is not considered
to be available if the coupling facility cannot accommodate the specified
SCMALGORITHM.
- SCMMAXSIZE REQUIREMENT MET BY PREFERRED CF
- This coupling facility does not have enough total storage-class
memory to accommodate the CFRM policy SCMMAXSIZE specification for
this structure, and there is another coupling facility which does.
Note that storage-class memory is not considered to be available
if the coupling facility cannot accommodate the specified SCMALGORITHM.
- MORE STORAGE-CLASS MEMORY AVAILABLE IN PREFERRED CF
- This coupling facility does not have enough storage-class memory
to allocate the structure with the amount specified by the CFRM policy
and there is another coupling facility that also does not have enough
storage-class memory but has more than this one. Note that storage-class
memory is not considered to be available if the coupling facility
cannot accommodate the specified SCMALGORITHM.
- MORE STORAGE-CLASS MEMORY CONFIGURED IN PREFERRED CF
- This coupling facility does not have enough total storage-class
memory to accommodate the CFRM policy SCMMAXSIZE specification for
this structure, and there is another coupling facility that also does
not have enough total storage-class memory but has more than this
one. Note that storage-class memory is not considered to be available
if the coupling facility cannot accommodate the specified SCMALGORITHM.
- NON-VOLATILITY REQUIREMENT MET BY PREFERRED CF
- This coupling facility is volatile, non-volatility was requested,
and at least one coupling facility exists coupling facility that is
non-volatile.
- FAILURE ISOLATION REQUIREMENT MET BY PREFERRED CF
- This coupling facility is not failure-isolated from all connectors,
non-volatility was requested, and at least one coupling facility exists
that is failure-isolated from all connectors.
- STAND-ALONE REQUIREMENT MET BY PREFERRED CF
- This coupling facility is not stand-alone, non-volatility was
requested, and at least one coupling facility exists that is stand-alone.
- EXCLLIST REQUIREMENT FULLY MET BY PREFERRED CF
- This coupling facility contains a structure from the EXCLLIST,
and at least one coupling facility exists that does not contain any
structures from the EXCLLIST.
- EXCLLIST REQUIREMENT MET BY PREFERRED CF
- This coupling facility contains a simplex structure from the EXCLLIST,
and at least one coupling facility exists that contains only old or
new structure instances from the EXCLLIST.
- REMOTE FACILITY SPACE REQUIREMENT MET BY PREFERRED CF
- The following conditions exist:
- System-managed duplexing rebuild is a possibility for the structure.
- The coupling facility is not connected by CF-to-CF links to any
other coupling facilities in the PREFLIST that have adequate space
to allocate the structure if a duplexing rebuild is to be started.
- At least one coupling facility exists that is connected by CF-to-CF
links to a coupling facility that does have adequate space to allocate
the structure.
- REMOTE FACILITY REQUIREMENT MET BY PREFERRED CF
- The following conditions exist:
- System-managed duplexing rebuild is a possibility for the structure.
- This coupling facility is not connected by CF-to-CF links to any
other coupling facilities in the PREFLIST,
- At least one coupling facility exists that is connected by CF-to-CF
links to a remote facility, but the remote facility does not have
adequate space to allocate the structure if a duplexing rebuild is
to be started.
- PREFERRED CF HIGHER IN PREFLIST
- This coupling facility is lower in the PREFLIST than another coupling
facility that is suitable for allocation.
- ENFORCEORDER(YES) AND PREFERRED CF HIGHER IN PREFLIST
- This coupling facility is lower in the PREFLIST than another coupling
facility that is suitable for allocation; because ENFORCEORDER(YES)
was also specified for the structure in the CFRM policy, XCF did not
re-order the PREFLIST.
- GREATER SFM WEIGHT CALCULATED FOR PREFERRED CF
- This coupling facility has a lower SFM weight than
another coupling facility that is suitable for allocation. For a
structure without any active connectors, the SFM weight of each coupling
facility is the sum of the SFM weights of all systems connected to
that coupling facility. For a structure with active connectors, only
systems with active connectors are used to determine the SFM weight
of the coupling facility. Note that all systems are considered to
have equal SFM weight if no SFM policy is active.
- RESTRICTED BY OPERATOR STOP OF DUPLEXING REBUILD
- The system did not select the coupling facility because the operator
had previously stopped the duplexing rebuild and the structure that
was not kept was allocated in this coupling facility.
- POPULATECF NOT SUITABLE
- The system did not select the coupling facility because it was
not as suitable as the facility in which the structure is currently
located.
- REBUILD IN PLACE NOT ALLOWED WITHOUT CFRM POLICY CHANGE
- The coupling facility contains the original instance of the structure,
and since there is no CFRM policy change pending, system-managed rebuild
into the same facility is not permitted.
- INSUFFICIENT CFLEVEL FOR CONNECTOR EXPLOITATION
- The coupling facility was not at or above the minimum required
CFLEVEL for the current set of active and failed-persistent connectors.
- INSUFFICIENT CFLEVEL FOR SYSTEM-MANAGED PROCESSING
- The coupling facility CFLEVEL was not at or above the minimum
required for the current system-managed process.
- INSUFFICIENT MAXIMUM NUMBER OF CONNECTIONS
- The maximum number of users that can connect to a structure in
this facility is less than the maximum number that can connect to
the original instance of the structure.
- RESTRICTED BY STRUCTURE LIMITS
- Maximum values for some structure attributes are limited by the
coupling facility in which they reside. At least one of these structure
limits for structures in this coupling facility is less than the corresponding
limit on the original instance of the structure.
- ALLOCATED ATTRIBUTES UNACCEPTABLE
- An attempt to allocate the new structure in the specified facility
resulted in a structure with attributes (for example, size or object
counts) less suitable than those of the old structure. Adjust
the CFRM policy size values to accommodate the attributes of the old
structure.
- COMPUTED STRUCTURE SIZE WAS NOT VALID
- When the structure size was computed from the required object
counts (for example, entries, elements, list headers, etc), the command
failed, or the computed maximum structure size required was larger
than the policy specified SIZE value plus a toleration amount.
- NO CF-TO-CF CONNECTIVITY FROM THE PRIMARY TO THIS CF
- When CF-to-CF link information was obtained from the CF containing
the rebuild old (primary) structure, this CF did not have connectivity
(via CF-to-CF link) to the CF containing the rebuild old structure
as required for system-managed duplexing rebuild.
- NO CF-TO-CF CONNECTIVITY FROM THIS CF TO THE PRIMARY
- When CF-to-CF link information was obtained from this CF, the
CF containing the rebuild old (primary) structure did not have connectivity
(via CF-to-CF link) to this CF as required for system-managed duplexing
rebuild.
- PREFERRED CF 1
- Using the XCF allocation criteria, the system selected this coupling
facility as the first CF. When evaluating the structure, the REALLOCATE
process will compare this CF to the CF containing the only instance
for a simplex structure or to the CF containing the old instance for
a duplexed structure.
- PREFERRED CF 2
- Using the XCF allocation criteria, the system selected this coupling
facility as the second CF. When evaluating the structure, the REALLOCATE
process will compare this CF to the CF containing the new instance
for a duplexed structure.
When the coupling facility
status is PREFERRED CF ALREADY SELECTED or PREFERRED CF 2, the message
displays one of the following lines that gives the primary reason
why this coupling facility was placed lower than the previous one
in the eligibility queue. Because of how different requirements are
weighted, this information does not imply that all coupling facilities
higher in the eligibility queue meet the requirement:
- CONNECTIVITY REQUIREMENT MET BY PREFERRED CF
- At least one connector to the current (old) structure does not
have connectivity to this coupling facility, or
the reporting system does not have connectivity, and there is
at least one coupling facility to which all connectors do have connectivity.
- CFLEVEL REQUIREMENT MET BY PREFERRED CF
- Another coupling facility was found with a more appropriate CF
level.
- FAILURE ISOLATION FOR DUPLEXING MET BY PREFERRED CF
- This coupling facility is not failure isolated for duplexing,
this is a duplexing rebuild, and at least one coupling facility exists
that is failure-isolated for duplexing.
- SPACE AVAILABLE FOR REQUESTED SIZE IN PREFERRED CF
- This coupling facility does not have enough free space to meet
the requested structure size, and at least one coupling facility exists
that does have enough free space to allocate the structure at the
requested size.
- SPACE AVAILABLE FOR MINIMUM SIZE IN PREFERRED CF
- This coupling facility does not have enough free space to meet
the minimum required structure size to allocate the new structure
instance based on the current object counts, and at least one coupling
facility exists that does have enough free space to allocate the structure
at the minimum size.
- SPACE AVAILABLE FOR CHANGED DATA IN PREFERRED CF
- This coupling facility does not have enough free space to meet
the minimum required structure size to allocate the new structure
instance based on the current in-use and changed object counts, and
at least one coupling facility exists that does have enough free space
to allocate the structure but with changed data only.
- MORE SPACE AVAILABLE IN PREFERRED CF
- This coupling facility does not have enough free space to allocate
the structure at the requested size, and at least one coupling facility
exists that also does not have enough free space but does have more
space than this one.
- STORAGE-CLASS MEMORY FOR OBJECTS AVAILABLE IN PREFERRED CF
- This coupling facility does not have enough free storage-class
memory to allocate the structure based on the current object counts,
and there is at least one coupling facility that does have sufficient
storage-class memory. Note that storage-class memory is not considered
to be available if the coupling facility cannot accommodate the specified
SCMALGORITHM.
- SCMMAXSIZE REQUIREMENT MET BY PREFERRED CF
- This coupling facility does not have enough total storage-class
memory to accommodate the CFRM policy SCMMAXSIZE specification for
this structure, and there is another coupling facility which does.
Note that storage-class memory is not considered to be available
if the coupling facility cannot accommodate the specified SCMALGORITHM.
- MORE STORAGE-CLASS MEMORY AVAILABLE IN PREFERRED CF
- This coupling facility does not have enough storage-class memory
to allocate the structure with the amount specified by the CFRM policy
and there is another coupling facility that also does not have enough
storage-class memory but has more than this one. Note that storage-class
memory is not considered to be available if the coupling facility
cannot accommodate the specified SCMALGORITHM.
- MORE STORAGE-CLASS MEMORY CONFIGURED IN PREFERRED CF
- This coupling facility does not have enough total storage-class
memory to accommodate the CFRM policy SCMMAXSIZE specification for
this structure, and there is another coupling facility that also does
not have enough total storage-class memory but has more than this
one. Note that storage-class memory is not considered to be available
if the coupling facility cannot accommodate the specified SCMALGORITHM.
- NON-VOLATILITY REQUIREMENT MET BY PREFERRED CF
- This coupling facility is volatile, non-volatility was requested,
and at least one coupling facility exists coupling facility that is
non-volatile.
- FAILURE ISOLATION REQUIREMENT MET BY PREFERRED CF
- This coupling facility is not failure-isolated from all connectors,
non-volatility was requested, and at least one coupling facility exists
that is failure-isolated from all connectors.
- STAND-ALONE REQUIREMENT MET BY PREFERRED CF
- This coupling facility is not stand-alone, non-volatility was
requested, and at least one coupling facility exists that is stand-alone.
- EXCLLIST REQUIREMENT FULLY MET BY PREFERRED CF
- This coupling facility contains a structure from the EXCLLIST,
and at least one coupling facility exists that does not contain any
structures from the EXCLLIST.
- EXCLLIST REQUIREMENT MET BY PREFERRED CF
- This coupling facility contains a simplex structure from the EXCLLIST,
and at least one coupling facility exists that contains only old or
new structure instances from the EXCLLIST.
- REMOTE FACILITY SPACE REQUIREMENT MET BY PREFERRED CF
- The following conditions exist:
- System-managed duplexing rebuild is a possibility for the structure.
- The coupling facility is not connected by CF-to-CF links to any
other coupling facilities in the PREFLIST that have adequate space
to allocate the structure if a duplexing rebuild is to be started.
- At least one coupling facility exists that is connected by CF-to-CF
links to a coupling facility that does have adequate space to allocate
the structure.
- REMOTE FACILITY REQUIREMENT MET BY PREFERRED CF
- The following conditions exist:
- System-managed duplexing rebuild is a possibility for the structure.
- This coupling facility is not connected by CF-to-CF links to any
other coupling facilities in the PREFLIST,
- At least one coupling facility exists that is connected by CF-to-CF
links to a remote facility, but the remote facility does not have
adequate space to allocate the structure if a duplexing rebuild is
to be started.
- PREFERRED CF HIGHER IN PREFLIST
- This coupling facility is lower in the PREFLIST than another coupling
facility that is suitable for allocation.
- ENFORCEORDER(YES) AND PREFERRED CF HIGHER IN PREFLIST
- This coupling facility is lower in the PREFLIST than another coupling
facility that is suitable for allocation; because ENFORCEORDER(YES)
was also specified for the structure in the CFRM policy, XCF did not
re-order the PREFLIST.
- GREATER SFM WEIGHT CALCULATED FOR PREFERRED CF
- This coupling facility has a lower SFM weight than another coupling
facility that is suitable for allocation.
- MAX STRUCTURES ALREADY ALLOCATED IN THIS CF
- All available structure slots in this CF are already being used.
- INSUFFICIENT STORAGE-CLASS MEMORY
- The old structure has objects in SCM and the CF can allocate objects
in SCM but cannot allocate all in-use objects (staying within the
SIZE policy constraint), given the total amount of SCM configured
to the CF.
- COMPUTED OBJECT COUNTS UNACCEPTABLE
- The old structure has objects in SCM and calculations show that
the CF cannot allocate all in-use objects and remain within the SIZE
and SCMMAXSIZE policy constraints.
- COMPUTED STRUCTURE SIZE WAS NOT VALID
- When the structure size was computed from the required object
counts (for example, entries, elements, list headers, etc), the command
failed, or the computed maximum structure size required was larger
than the policy specified SIZE value plus a toleration amount. If
the CFRM policy specifies SCMMAXSIZE for the affected structure, this
text may also indicate that the coupling facility could not provide
sufficient storage-class memory for overflow of in-use structure objects
that cannot be contained within the structure itself.
- INFO110:
- One or more lines of additional diagnostic data may supplement
the coupling facility status line to provide rationale for the selection
or rejection of the named coupling facility.
- data1
- Diagnostic data to be used by IBM in
evaluating structure allocation processing.
- data2
- Diagnostic data to be used by IBM in
evaluating structure allocation processing. This fullword is a description
of the attributes of the 'current' CF. This fullword is also supplied
as the reason on IXL015I.
- BYTE1:
- 10000000
- This CF is accessible to the system trying to allocate the structure.
For a rebuild request it means that this facility is accessible to
all systems on which connections to the old structure are running.
- 01110000
- Indication of the suitability of the CF level of this CF for the
likely types of connections and services required.
- 00001000
- Duplex Failure Isolation indication if this bit is On then the
facility is isolated from the old structure OR this is not a duplex-rebuild-connect
request.
- 00000111
- Indication that this CF has sufficient space.
- 000000100
- Free space is sufficient.
- 000000010
- Enough free and control space to allocate the minimum required
structure size.
- 000000001
- Enough space to allocate the cache structure with "changed data"
only.
- BYTE2: Reserved for future use.
- BYTE3:
- 10000000
- CF operational level is lower than that specified by the connection
or is lower than that required for system managed processing.
- 01000000
- If on, Facility satisfies the volatility requirement as specified
by the connector
- 00100000
- If on, the facility is a stand-alone CF, and as such is failure
isolated from all MVS™ systems
- 00010000
- Indicates that the facility satisfies the failure isolation requirement
as specified by the connector
- 00001100
- Indication of how closely the exclusion list requirement is met.
These two bits break down as follows:
- 10
- CF contains no instances of any structures from the exclusion
list.
- 01
- CF contains instances of structures from the exclusion list, but
each is one of 2 instances
- 00
- CF contains the only instance of one or more structures from the
exclusion list.
- 00000010
- System managed duplexing rebuild is a possibility if the structure
is allocated on this CF as there is another CF available with sufficient
storage and connected by peer links for the allocation of a secondary
structure in the future, should a duplexing rebuild be started in
the future.
- 00000001
- Same as above except that sufficient storage is not included in
the description.
- BYTE4: NOT RELEVANT.
- data3
- Diagnostic data to be used by IBM in
evaluating structure allocation processing. This fullword are those
attributes that the target CF didn't have that the current CF did.
Thus the meanings are the exact opposite of those described for the
2nd fullword.
- data4
- Diagnostic data to be used by IBM in
evaluating structure allocation processing.
- data5
- Diagnostic data to be used by IBM in
evaluating structure allocation processing.
- data6
- Diagnostic data to be used by IBM in
evaluating structure allocation processing.
- subreason
- One or more subreason lines appear when the coupling facility
status is ALLOCATION NOT PERMITTED. subreason is
one of the following:
- COUPLING FACILITY BEING REMOVED
- The coupling facility is in the process of being removed from
the CFRM active policy.
- COUPLING FACILITY BEING RECONCILED
- The coupling facility is in the process of being cleaned up due
to couple data set serialization.
- CFRM INDICATES COUPLING FACILITY FAILURE
- The coupling facility has failed. All data in the coupling facility
is lost.
- COUPLING FACILITY IS IN MAINTENANCE MODE
- The coupling facility is in maintenance mode.
System action
For REALLOCATE processing or when
the allocation was successful for structure rebuild processing, the
system continues the in-progress process. When the allocation failed
or was not feasible, the system terminates the structure rebuild
process.
Operator response
Contact the system programmer
for advice and assistance if messages IXC367I, IXC528I, IXC538I, or
IXC573I indicate the structure rebuild process could not continue.
System programmer response
For the REALLOCATE process,
evaluation of the specified structure will be completed to determine
whether or not there is a need to adjust the location of the structure
instance(s). Refer to the description for message IXC543I, which provides
an explanation of the messages issued during REALLOCATE processing.
For the specified type of structure rebuild processing
which is being started or in progress, refer to the description for
message IXC367I, IXC528I, IXC538I, IXC573I, IXC578I, or
IXC582I,as appropriate.
If the rebuild new structure was
successfully allocated no action is required.
If
the rebuild new structure allocation failed or was not feasible, examine
the diagnostic information provided for each coupling facility by
the message and the ConaFacilityArray section of the LOGREC symptom
record, if any. Determine why there are no coupling facilities in
which to allocate the rebuild new structure. If the failure occurs
because of a possible problem with the CFRM policy size values, ensure
that the values specified are sufficient to accommodate the attributes
of the original structure. The following references provide information
for sizing coupling facility structures:
Correct the conditions that caused the error, and either
start the structure rebuild process again, or wait for MVS to automatically initiate a duplexing rebuild
for the structure.
If the conditions that caused the error
cannot be determined, contact the IBM support
center. Supply the error data included in the message, along with
other data from the system log.
Source
Cross System Coupling Facility (SCXCF)
Module
Routing code
Descriptor code