IXC574I
text OF STRUCTURE strname[ AUTO VERSION: procid1 procid2] [stralloc STRUCTURE ALLOCATED IN COUPLING FACILITY: cfname1 cfname2]Start of change[polinfo]End of changetext2

Explanation

For the specified structure, either the REALLOCATE process was evaluating the structure or a structure rebuild process of the specified type was being started or in progress. This message provides further information about the evaluation, feasibility, or allocation decision based on the coupling facilities in the structure's preference list.

When sorting the CF eligibility queue for all system-managed rebuild processing and reallocate processing, SFM weight is given priority over other attributes. For a structure without any active connectors, the SFM weight of each coupling facility is the sum of the SFM weights of all systems connected to that coupling facility. For a structure with active connectors, only systems with active connectors are used to determine the SFM weight of the coupling facility. All systems are considered to have equal SFM weight if no SFM policy is active.

Note that for a POPULATECF rebuild request, only the POPULATECF is considered as a possible location for the new instance of the structure, and only that coupling facility will be listed.

In the message text:

text
One of the following:
ALLOCATION INFORMATION FOR SYSTEM-MANAGED REBUILD
A system-managed rebuild was in progress for the specified structure. This system attempted to allocate the rebuild new instance of the structure, and succeeded or failed as described by messageIXC578I and IXC582I, or IXC573I, respectively.
ALLOCATION INFORMATION FOR SYSTEM-MANAGED DUPLEXING REBUILD
A system-managed duplexing rebuild was in progress for the specified structure. This system attempted to allocate the rebuild new instance of the structure, and succeeded or failed as described by message IXC578I and IXC582I, or IXC573I, respectively.
ALLOCATION FEASIBILITY INFORMATION FOR DUPLEXING REBUILD
A request to start a user-managed duplexing rebuild for the specified structure was being processed. This system determined that allocation of the rebuild new structure instance was not feasible.
EVALUATION INFORMATION FOR REALLOCATE PROCESSING
The REALLOCATE process is evaluating an allocated structure using the XCF allocation criteria to analyze the coupling facilities in the preferred list. The preferred coupling facilities are used in determining whether the location of the structure instance(s) should be adjusted by using structure rebuild processing.
strname
Name of the structure for which information is recorded.
AUTO VERSION:
A unique value identifying the system-managed process in progress. It can be used to correlate messages and XCF component trace records associated with the current system-managed process.
procid1
First half of the auto version.
procid2
Second half of the auto version.
stralloc
One of the following:
SIMPLEX
The structure is simplex with one instance allocated.
DUPLEXED
The structure is duplexed with two instances allocated.
cfname1
Name of coupling facility from the CFRM active policy. For a simplex structure, this is the name of the coupling facility containing the only instance. For a duplexed structure, this is the name of the coupling facility containing the old instance.
cfname2
Name of coupling facility from the CFRM active policy. For a simplex structure, this is blank. For a duplexed structure, this is the name of the coupling facility containing the new instance.
Start of changepolinfoEnd of change
Start of changeOne of the following:
ACTIVE POLICY INFORMATION USED.
The current active policy definition was used.
PENDING POLICY INFORMATION USED.
The pending policy definition was used.
ACTIVE POLICY INFORMATION USED BUT EXCLUSION LIST WAS IGNORED.
The current active policy definition for the structure was used but the exclusion list was ignored.
PENDING POLICY INFORMATION USED BUT EXCLUSION LIST WAS IGNORED.
The pending policy definition for the structure was used but the exclusion list was ignored.
End of change
text2
CFNAME             STATUS/FAILURE REASON
---------         ------------------------------------------------------
cfname              status
                             [INFO110: data1 data2 data3]
                                          [data 4 data5 data6]

                             [subreason]
cfname
Name of the coupling facility for which information is recorded.
status
One of the following:
STRUCTURE ALLOCATED
Structure was successfully allocated in the specified coupling facility.
NO CONNECTIVITY
The CFRM active policy indicates that this system does not have connectivity to the specified coupling facility. This message may be accompanied by message IXC575I, indicating that another system will attempt to allocate the structure. That system will also issue message IXC574I to record the results of its allocation attempt. If no system succeeded in allocating the structure, re-establish physical connectivity to the coupling facility and re-initiate the system-managed process for which allocation was attempted.
COUPLING FACILITY NOT IN ACTIVE POLICY
The coupling facility is not listed in the active policy so it is not viable until the policy is changed.
CONNECTIVITY LOST
An attempt to allocate the structure in this coupling facility was unsuccessful because connectivity to the coupling facility has been lost. If structure allocation failed, establish physical connectivity to the coupling facility and reinitiate the system-managed process for which allocation was attempted.
COUPLING FACILITY FAILURE
The coupling facility has failed.
STRUCTURE FAILURE
The new instance of the structure failed during the allocation process.
PARAMETER ERROR
The requested structure attributes are inconsistent with the model-dependent attributes of the coupling facility. Contact IBM® service.
INVALID STRUCTURE SIZE
The target structure size was too small to allocate the structure with the attributes specified. If the allocation failed, the CONAFACILITYMINREQSIZE field of the ConaFacilityArray section of the LOGREC symptom record provided with message IXC573I is set to the minimum Start of changesize of the structure if it were to be allocatedEnd of change in this coupling facility with the requested attributes. Start of changeThe amount of storage required by the structure also increases as a function of the CFRM policy SCMMAXSIZE specification. Requesting a large amount of storage-class memory can significantly increase the minimum structure size.End of change Increase the maximum structure size specified in the CFRM policy.
ALLOCATION NOT PERMITTED
New structures cannot be allocated in the coupling facility according to the CFRM active policy. One or more subreason message lines explain why the structure cannot be allocated in the specified coupling facility.
XCF COMPONENT ERROR
An XCF component error has occurred. Contact IBM service.
UNKNOWN HARDWARE ERROR
An unknown hardware error has occurred. Contact IBM service.
INSUFFICIENT SPACE
There was not sufficient space in the coupling facility to allocate the structure. If structure allocation failed, examine the ConaFacilityArray section of the LOGREC symptom record provided with message IXC573I. CONAFACILITYMINREQSIZE is set to the minimum Start of changesize of the structure if it were to be allocatedEnd of change in this coupling facility with the requested attributes. Start of changeThe amount of storage required by the structure also increases as a function of the CFRM policy SCMMAXSIZE specification. Requesting a large amount of storage-class memory can significantly increase the minimum structure size. Some amount of additional storage, over and above the structure size, may also be required to support storage-class memory.End of change Make sure there is a coupling facility in the structure's preference list with sufficient space.
RESTRICTED BY REBUILD OTHER
LOCATION=OTHER was specified on the rebuild request. Since the original structure was allocated in this coupling facility, the system did not use this coupling facility when trying to allocate the new structure for rebuild. If the structure allocation failed, make sure there is another suitable coupling facility in the structure's preference list.
INSUFFICIENT CONNECTIVITY
The coupling facility does not provide connectivity at least equivalent to the connectivity provided by the coupling facility in which the original structure resided.
PREFERRED CF ALREADY SELECTED
The system did not select the coupling facility because a preferable coupling facility was already selected. When the coupling facility status is PREFERRED CF ALREADY SELECTED or PREFERRED CF 2, the message displays one of the following lines that gives the primary reason why this coupling facility was placed lower than the previous one in the eligibility queue. Because of how different requirements are weighted, this information does not imply that all coupling facilities higher in the eligibility queue meet the requirement:
CONNECTIVITY REQUIREMENT MET BY PREFERRED CF
At least one connector to the current (old) structure does not have connectivity to this coupling facility, Start of changeor the reporting system does not have connectivityEnd of change, and there is at least one coupling facility to which all connectors do have connectivity.
CFLEVEL REQUIREMENT MET BY PREFERRED CF
Another coupling facility was found with a more appropriate CF level.
FAILURE ISOLATION FOR DUPLEXING MET BY PREFERRED CF
This coupling facility is not failure isolated for duplexing, this is a duplexing rebuild, and at least one coupling facility exists that is failure-isolated for duplexing.
SPACE AVAILABLE FOR REQUESTED SIZE IN PREFERRED CF
This coupling facility does not have enough free space to meet the requested structure size, and at least one coupling facility exists that does have enough free space to allocate the structure at the requested size.
SPACE AVAILABLE FOR MINIMUM SIZE IN PREFERRED CF
This coupling facility does not have enough free space to meet the minimum required structure size to allocate the new structure instance based on the current object counts, and at least one coupling facility exists that does have enough free space to allocate the structure at the minimum size.
SPACE AVAILABLE FOR CHANGED DATA IN PREFERRED CF
This coupling facility does not have enough free space to meet the minimum required structure size to allocate the new structure instance based on the current in-use and changed object counts, and at least one coupling facility exists that does have enough free space to allocate the structure but with changed data only.
MORE SPACE AVAILABLE IN PREFERRED CF
This coupling facility does not have enough free space to allocate the structure at the requested size, and at least one coupling facility exists that also does not have enough free space but does have more space than this one.
Start of changeStart of changeSTORAGE-CLASS MEMORY REQUIREMENT MET BY PREFERRED CFEnd of changeEnd of change
Start of changeThis coupling facility does not have enough free storage-class memory to allocate the structure based on the current object counts, and there is at least one coupling facility that does have sufficient storage-class memory. Note that storage-class memory is not considered to be available if the coupling facility cannot accommodate the specified SCMALGORITHM.End of change
Start of changeSCMMAXSIZE REQUIREMENT MET BY PREFERRED CFEnd of change
Start of changeThis coupling facility does not have enough total storage-class memory to accommodate the CFRM policy SCMMAXSIZE specification for this structure, and there is another coupling facility which does. Note that storage-class memory is not considered to be available if the coupling facility cannot accommodate the specified SCMALGORITHM.End of change
Start of changeMORE STORAGE-CLASS MEMORY AVAILABLE IN PREFERRED CFEnd of change
Start of changeThis coupling facility does not have enough storage-class memory to allocate the structure with the amount specified by the CFRM policy and there is another coupling facility that also does not have enough storage-class memory but has more than this one. Note that storage-class memory is not considered to be available if the coupling facility cannot accommodate the specified SCMALGORITHM.End of change
Start of changeMORE STORAGE-CLASS MEMORY CONFIGURED IN PREFERRED CFEnd of change
Start of changeThis coupling facility does not have enough total storage-class memory to accommodate the CFRM policy SCMMAXSIZE specification for this structure, and there is another coupling facility that also does not have enough total storage-class memory but has more than this one. Note that storage-class memory is not considered to be available if the coupling facility cannot accommodate the specified SCMALGORITHM.End of change
NON-VOLATILITY REQUIREMENT MET BY PREFERRED CF
This coupling facility is volatile, non-volatility was requested, and at least one coupling facility exists coupling facility that is non-volatile.
FAILURE ISOLATION REQUIREMENT MET BY PREFERRED CF
This coupling facility is not failure-isolated from all connectors, non-volatility was requested, and at least one coupling facility exists that is failure-isolated from all connectors.
STAND-ALONE REQUIREMENT MET BY PREFERRED CF
This coupling facility is not stand-alone, non-volatility was requested, and at least one coupling facility exists that is stand-alone.
EXCLLIST REQUIREMENT FULLY MET BY PREFERRED CF
This coupling facility contains a structure from the EXCLLIST, and at least one coupling facility exists that does not contain any structures from the EXCLLIST.
EXCLLIST REQUIREMENT MET BY PREFERRED CF
This coupling facility contains a simplex structure from the EXCLLIST, and at least one coupling facility exists that contains only old or new structure instances from the EXCLLIST.
REMOTE FACILITY SPACE REQUIREMENT MET BY PREFERRED CF
The following conditions exist:
  • System-managed duplexing rebuild is a possibility for the structure.
  • The coupling facility is not connected by CF-to-CF links to any other coupling facilities in the PREFLIST that have adequate space to allocate the structure if a duplexing rebuild is to be started.
  • At least one coupling facility exists that is connected by CF-to-CF links to a coupling facility that does have adequate space to allocate the structure.
REMOTE FACILITY REQUIREMENT MET BY PREFERRED CF
The following conditions exist:
  • System-managed duplexing rebuild is a possibility for the structure.
  • This coupling facility is not connected by CF-to-CF links to any other coupling facilities in the PREFLIST,
  • At least one coupling facility exists that is connected by CF-to-CF links to a remote facility, but the remote facility does not have adequate space to allocate the structure if a duplexing rebuild is to be started.
PREFERRED CF HIGHER IN PREFLIST
This coupling facility is lower in the PREFLIST than another coupling facility that is suitable for allocation.
ENFORCEORDER(YES) AND PREFERRED CF HIGHER IN PREFLIST
This coupling facility is lower in the PREFLIST than another coupling facility that is suitable for allocation; because ENFORCEORDER(YES) was also specified for the structure in the CFRM policy, XCF did not re-order the PREFLIST.
GREATER SFM WEIGHT CALCULATED FOR PREFERRED CF
This coupling facility has a lower SFM weight than another coupling facility that is suitable for allocation. For a structure without any active connectors, the SFM weight of each coupling facility is the sum of the SFM weights of all systems connected to that coupling facility. For a structure with active connectors, only systems with active connectors are used to determine the SFM weight of the coupling facility. Note that all systems are considered to have equal SFM weight if no SFM policy is active.
RESTRICTED BY OPERATOR STOP OF DUPLEXING REBUILD
The system did not select the coupling facility because the operator had previously stopped the duplexing rebuild and the structure that was not kept was allocated in this coupling facility.
POPULATECF NOT SUITABLE
The system did not select the coupling facility because it was not as suitable as the facility in which the structure is currently located.
REBUILD IN PLACE NOT ALLOWED WITHOUT CFRM POLICY CHANGE
The coupling facility contains the original instance of the structure, and since there is no CFRM policy change pending, system-managed rebuild into the same facility is not permitted.
INSUFFICIENT CFLEVEL FOR CONNECTOR EXPLOITATION
The coupling facility was not at or above the minimum required CFLEVEL for the current set of active and failed-persistent connectors.
INSUFFICIENT CFLEVEL FOR SYSTEM-MANAGED PROCESSING
The coupling facility CFLEVEL was not at or above the minimum required for the current system-managed process.
INSUFFICIENT MAXIMUM NUMBER OF CONNECTIONS
The maximum number of users that can connect to a structure in this facility is less than the maximum number that can connect to the original instance of the structure.
RESTRICTED BY STRUCTURE LIMITS
Maximum values for some structure attributes are limited by the coupling facility in which they reside. At least one of these structure limits for structures in this coupling facility is less than the corresponding limit on the original instance of the structure.
ALLOCATED ATTRIBUTES UNACCEPTABLE
An attempt to allocate the new structure in the specified facility resulted in a structure with attributes (for example, size or object counts) less suitable than those of the old structure. Adjust the CFRM policy size values to accommodate the attributes of the old structure.
COMPUTED STRUCTURE SIZE WAS NOT VALID
When the structure size was computed from the required object counts (for example, entries, elements, list headers, etc), the command failed, or the computed maximum structure size required was larger than the policy specified SIZE value plus a toleration amount.
NO CF-TO-CF CONNECTIVITY FROM THE PRIMARY TO THIS CF
When CF-to-CF link information was obtained from the CF containing the rebuild old (primary) structure, this CF did not have connectivity (via CF-to-CF link) to the CF containing the rebuild old structure as required for system-managed duplexing rebuild.
NO CF-TO-CF CONNECTIVITY FROM THIS CF TO THE PRIMARY
When CF-to-CF link information was obtained from this CF, the CF containing the rebuild old (primary) structure did not have connectivity (via CF-to-CF link) to this CF as required for system-managed duplexing rebuild.
PREFERRED CF 1
Using the XCF allocation criteria, the system selected this coupling facility as the first CF. When evaluating the structure, the REALLOCATE process will compare this CF to the CF containing the only instance for a simplex structure or to the CF containing the old instance for a duplexed structure.
PREFERRED CF 2
Using the XCF allocation criteria, the system selected this coupling facility as the second CF. When evaluating the structure, the REALLOCATE process will compare this CF to the CF containing the new instance for a duplexed structure.
When the coupling facility status is PREFERRED CF ALREADY SELECTED or PREFERRED CF 2, the message displays one of the following lines that gives the primary reason why this coupling facility was placed lower than the previous one in the eligibility queue. Because of how different requirements are weighted, this information does not imply that all coupling facilities higher in the eligibility queue meet the requirement:
CONNECTIVITY REQUIREMENT MET BY PREFERRED CF
At least one connector to the current (old) structure does not have connectivity to this coupling facility, Start of changeor the reporting system does not have connectivity,End of change and there is at least one coupling facility to which all connectors do have connectivity.
CFLEVEL REQUIREMENT MET BY PREFERRED CF
Another coupling facility was found with a more appropriate CF level.
FAILURE ISOLATION FOR DUPLEXING MET BY PREFERRED CF
This coupling facility is not failure isolated for duplexing, this is a duplexing rebuild, and at least one coupling facility exists that is failure-isolated for duplexing.
SPACE AVAILABLE FOR REQUESTED SIZE IN PREFERRED CF
This coupling facility does not have enough free space to meet the requested structure size, and at least one coupling facility exists that does have enough free space to allocate the structure at the requested size.
SPACE AVAILABLE FOR MINIMUM SIZE IN PREFERRED CF
This coupling facility does not have enough free space to meet the minimum required structure size to allocate the new structure instance based on the current object counts, and at least one coupling facility exists that does have enough free space to allocate the structure at the minimum size.
SPACE AVAILABLE FOR CHANGED DATA IN PREFERRED CF
This coupling facility does not have enough free space to meet the minimum required structure size to allocate the new structure instance based on the current in-use and changed object counts, and at least one coupling facility exists that does have enough free space to allocate the structure but with changed data only.
MORE SPACE AVAILABLE IN PREFERRED CF
This coupling facility does not have enough free space to allocate the structure at the requested size, and at least one coupling facility exists that also does not have enough free space but does have more space than this one.
Start of changeSTORAGE-CLASS MEMORY FOR OBJECTS AVAILABLE IN PREFERRED CFEnd of change
Start of changeThis coupling facility does not have enough free storage-class memory to allocate the structure based on the current object counts, and there is at least one coupling facility that does have sufficient storage-class memory. Note that storage-class memory is not considered to be available if the coupling facility cannot accommodate the specified SCMALGORITHM.End of change
Start of changeSCMMAXSIZE REQUIREMENT MET BY PREFERRED CFEnd of change
Start of changeThis coupling facility does not have enough total storage-class memory to accommodate the CFRM policy SCMMAXSIZE specification for this structure, and there is another coupling facility which does. Note that storage-class memory is not considered to be available if the coupling facility cannot accommodate the specified SCMALGORITHM.End of change
Start of changeMORE STORAGE-CLASS MEMORY AVAILABLE IN PREFERRED CFEnd of change
Start of changeThis coupling facility does not have enough storage-class memory to allocate the structure with the amount specified by the CFRM policy and there is another coupling facility that also does not have enough storage-class memory but has more than this one. Note that storage-class memory is not considered to be available if the coupling facility cannot accommodate the specified SCMALGORITHM.End of change
Start of changeMORE STORAGE-CLASS MEMORY CONFIGURED IN PREFERRED CFEnd of change
Start of changeThis coupling facility does not have enough total storage-class memory to accommodate the CFRM policy SCMMAXSIZE specification for this structure, and there is another coupling facility that also does not have enough total storage-class memory but has more than this one. Note that storage-class memory is not considered to be available if the coupling facility cannot accommodate the specified SCMALGORITHM.End of change
NON-VOLATILITY REQUIREMENT MET BY PREFERRED CF
This coupling facility is volatile, non-volatility was requested, and at least one coupling facility exists coupling facility that is non-volatile.
FAILURE ISOLATION REQUIREMENT MET BY PREFERRED CF
This coupling facility is not failure-isolated from all connectors, non-volatility was requested, and at least one coupling facility exists that is failure-isolated from all connectors.
STAND-ALONE REQUIREMENT MET BY PREFERRED CF
This coupling facility is not stand-alone, non-volatility was requested, and at least one coupling facility exists that is stand-alone.
EXCLLIST REQUIREMENT FULLY MET BY PREFERRED CF
This coupling facility contains a structure from the EXCLLIST, and at least one coupling facility exists that does not contain any structures from the EXCLLIST.
EXCLLIST REQUIREMENT MET BY PREFERRED CF
This coupling facility contains a simplex structure from the EXCLLIST, and at least one coupling facility exists that contains only old or new structure instances from the EXCLLIST.
REMOTE FACILITY SPACE REQUIREMENT MET BY PREFERRED CF
The following conditions exist:
  • System-managed duplexing rebuild is a possibility for the structure.
  • The coupling facility is not connected by CF-to-CF links to any other coupling facilities in the PREFLIST that have adequate space to allocate the structure if a duplexing rebuild is to be started.
  • At least one coupling facility exists that is connected by CF-to-CF links to a coupling facility that does have adequate space to allocate the structure.
REMOTE FACILITY REQUIREMENT MET BY PREFERRED CF
The following conditions exist:
  • System-managed duplexing rebuild is a possibility for the structure.
  • This coupling facility is not connected by CF-to-CF links to any other coupling facilities in the PREFLIST,
  • At least one coupling facility exists that is connected by CF-to-CF links to a remote facility, but the remote facility does not have adequate space to allocate the structure if a duplexing rebuild is to be started.
PREFERRED CF HIGHER IN PREFLIST
This coupling facility is lower in the PREFLIST than another coupling facility that is suitable for allocation.
ENFORCEORDER(YES) AND PREFERRED CF HIGHER IN PREFLIST
This coupling facility is lower in the PREFLIST than another coupling facility that is suitable for allocation; because ENFORCEORDER(YES) was also specified for the structure in the CFRM policy, XCF did not re-order the PREFLIST.
GREATER SFM WEIGHT CALCULATED FOR PREFERRED CF
This coupling facility has a lower SFM weight than another coupling facility that is suitable for allocation.
Start of changeMAX STRUCTURES ALREADY ALLOCATED IN THIS CFEnd of change
Start of changeAll available structure slots in this CF are already being used.End of change
Start of changeINSUFFICIENT STORAGE-CLASS MEMORYEnd of change
Start of changeThe old structure has objects in SCM and the CF can allocate objects in SCM but cannot allocate all in-use objects (staying within the SIZE policy constraint), given the total amount of SCM configured to the CF.End of change
Start of changeCOMPUTED OBJECT COUNTS UNACCEPTABLEEnd of change
Start of changeThe old structure has objects in SCM and calculations show that the CF cannot allocate all in-use objects and remain within the SIZE and SCMMAXSIZE policy constraints.End of change
Start of changeCOMPUTED STRUCTURE SIZE WAS NOT VALIDEnd of change
Start of changeWhen the structure size was computed from the required object counts (for example, entries, elements, list headers, etc), the command failed, or the computed maximum structure size required was larger than the policy specified SIZE value plus a toleration amount. If the CFRM policy specifies SCMMAXSIZE for the affected structure, this text may also indicate that the coupling facility could not provide sufficient storage-class memory for overflow of in-use structure objects that cannot be contained within the structure itself.End of change
INFO110:
One or more lines of additional diagnostic data may supplement the coupling facility status line to provide rationale for the selection or rejection of the named coupling facility.
data1
Diagnostic data to be used by IBM in evaluating structure allocation processing.
data2
Diagnostic data to be used by IBM in evaluating structure allocation processing. This fullword is a description of the attributes of the 'current' CF. This fullword is also supplied as the reason on IXL015I.
  • BYTE1:
    10000000
    This CF is accessible to the system trying to allocate the structure. For a rebuild request it means that this facility is accessible to all systems on which connections to the old structure are running.
    01110000
    Indication of the suitability of the CF level of this CF for the likely types of connections and services required.
    00001000
    Duplex Failure Isolation indication if this bit is On then the facility is isolated from the old structure OR this is not a duplex-rebuild-connect request.
    00000111
    Indication that this CF has sufficient space.
    000000100
    Free space is sufficient.
    000000010
    Enough free and control space to allocate the minimum required structure size.
    000000001
    Enough space to allocate the cache structure with "changed data" only.
  • BYTE2: Reserved for future use.
  • BYTE3:
    10000000
    CF operational level is lower than that specified by the connection or is lower than that required for system managed processing.
    01000000
    If on, Facility satisfies the volatility requirement as specified by the connector
    00100000
    If on, the facility is a stand-alone CF, and as such is failure isolated from all MVS™ systems
    00010000
    Indicates that the facility satisfies the failure isolation requirement as specified by the connector
    00001100
    Indication of how closely the exclusion list requirement is met. These two bits break down as follows:
    10
    CF contains no instances of any structures from the exclusion list.
    01
    CF contains instances of structures from the exclusion list, but each is one of 2 instances
    00
    CF contains the only instance of one or more structures from the exclusion list.
    00000010
    System managed duplexing rebuild is a possibility if the structure is allocated on this CF as there is another CF available with sufficient storage and connected by peer links for the allocation of a secondary structure in the future, should a duplexing rebuild be started in the future.
    00000001
    Same as above except that sufficient storage is not included in the description.
  • BYTE4: NOT RELEVANT.
data3
Diagnostic data to be used by IBM in evaluating structure allocation processing. This fullword are those attributes that the target CF didn't have that the current CF did. Thus the meanings are the exact opposite of those described for the 2nd fullword.
data4
Diagnostic data to be used by IBM in evaluating structure allocation processing.
data5
Diagnostic data to be used by IBM in evaluating structure allocation processing.
data6
Diagnostic data to be used by IBM in evaluating structure allocation processing.
subreason
One or more subreason lines appear when the coupling facility status is ALLOCATION NOT PERMITTED. subreason is one of the following:
COUPLING FACILITY BEING REMOVED
The coupling facility is in the process of being removed from the CFRM active policy.
COUPLING FACILITY BEING RECONCILED
The coupling facility is in the process of being cleaned up due to couple data set serialization.
CFRM INDICATES COUPLING FACILITY FAILURE
The coupling facility has failed. All data in the coupling facility is lost.
COUPLING FACILITY IS IN MAINTENANCE MODE
The coupling facility is in maintenance mode.

System action

For REALLOCATE processing or when the allocation was successful for structure rebuild processing, the system continues the in-progress process. When the allocation failed or was not feasible, the system terminates the structure rebuild process.

Operator response

Contact the system programmer for advice and assistance if messages IXC367I, IXC528I, IXC538I, or IXC573I indicate the structure rebuild process could not continue.

System programmer response

For the REALLOCATE process, evaluation of the specified structure will be completed to determine whether or not there is a need to adjust the location of the structure instance(s). Refer to the description for message IXC543I, which provides an explanation of the messages issued during REALLOCATE processing.

For the specified type of structure rebuild processing which is being started or in progress, refer to the description for message IXC367I, IXC528I, IXC538I, IXC573I, IXC578I, or IXC582I,as appropriate.

If the rebuild new structure was successfully allocated no action is required.

If the rebuild new structure allocation failed or was not feasible, examine the diagnostic information provided for each coupling facility by the message and the ConaFacilityArray section of the LOGREC symptom record, if any. Determine why there are no coupling facilities in which to allocate the rebuild new structure. If the failure occurs because of a possible problem with the CFRM policy size values, ensure that the values specified are sufficient to accommodate the attributes of the original structure. The following references provide information for sizing coupling facility structures:

Correct the conditions that caused the error, and either start the structure rebuild process again, or wait for MVS to automatically initiate a duplexing rebuild for the structure.

If the conditions that caused the error cannot be determined, contact the IBM support center. Supply the error data included in the message, along with other data from the system log.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCL2ATH

Routing code

2