IXC111I
LOGICAL PARTITION REMOTE CONNECTION INFORMATIONinformation

Explanation

In the message, information is:
CONNECTION STATUS:    {CONNECTED | NOT CONNECTED}  
SYSTEM NAME:          sysname 
SYSTEM NUMBER:        sysnum 
IMAGE NAME:           image 
NETWORK ADDRESS:      netid.nau
IPL TOKEN:            ipltoken
DIAG INFO:            diaginfo

The message displays identification information associated with a system in the sysplex, and the local system connection status to that system for the purposes of employing the system status detection partitioning protocol.

In the message text:
CONNECTED
The local system is connected to remote CPC image image through BCPii callable services.
NOT CONNECTED
The local system is not connected to remote CPC image image through BCPii callable services. The local system cannot target remote CPC image image with the system status detection partitioning protocol.
sysname
The name of the system in the sysplex that the remotely connected status pertains to.
sysnum
The XCF system number assigned to the remote system sysname.
image
The image name associated with the remote system sysname in the sysplex.
netid
The network ID of the local area network (LAN) connecting CPCs on which the systems in the sysplex reside.
nau
The network addressable unit uniquely identifying an image as a node on the LAN named by netid.
ipltoken
The IPL token assigned to system sysname in the sysplex. The IPL token uniquely identifies the system instance of sysname in the sysplex.
diaginfo
The diagnostic information applicable when the connection status indicates that the local system is not connected to the remote system sysname and CPC image image through BCPii callable services. The diagnostic data returned by the BCPii callable service can help determine the cause of the failed connection request. The diagnostic information contains the following data:
  • The name of the BCPii callable service that failed when the local system attempted to establish a connection to another CPC or image in the sysplex.
  • An error return code that was returned by the BCPii callable service that failed while the local system was attempting to establish a connection to a CPC or image. See z/OS MVS Programming: Callable Services for High-Level Languages for more information about BCPii services return codes and actions to take in the event of a specific return code.
  • A diagnostic data area returned by the BCPii callable service, which contains information related to the BCPii service that failed.

System action

The system continues processing. If the system status detection partitioning protocol cannot be used, the system processes partitioning requests using a partitioning protocol based on the sysplex failure management (SFM) policy or default indeterminate status behavior. XCF will reattempt the failed request after a certain time interval to allow for corrections to be made in the system environment.

Operator response

Notify the system programmer.

System programmer response

If the connection status is NOT CONNECTED, see z/OS MVS Programming: Callable Services for High-Level Languages for detailed information about return codes for BCPii callable services. Determine the reason why the BCPii callable service shown in the diaginfo returned an unsuccessful return code and make the appropriate corrections.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCS2SBT

Routing code

2, Note 13

Descriptor code

4