IXC109I
{FENCE | SYSTEM RESET} OF SYSTEM sysname {SUCCESSFUL. | RESULTS: | TIMED OUT.} [{HWICMD|HWMCA_EVENT_ COMMAND_RESPONSE} RETURN CODE: retcode] text

Explanation

Action was taken to ensure that a system being partitioned from the sysplex no longer has the capability to perform I/O to devices that can be used by another active system in the sysplex. Message IXC108I was issued when the action was initiated. This message is issued when the results of the action are available or the action times out.

In the message text:
FENCE
The action is system isolation by a system fence through coupling facility fencing services.
SYSTEM RESET
The action is a SYSTEM RESET-NORMAL through the HWICMD BCPii callable service.
sysname
The name of the system targeted by the action.
SUCCESSFUL.
The action completed successfully.
RESULTS:
The action resulted in the indicated return code.
TIMED OUT.
The action did not complete within the allotted time. Processing continues without the result of the action.
HWICMD
The action resulted in the indicated HWICMD BCPii callable service return code.
HWMCA_EVENT_COMMAND_RESPONSE
The action resulted in the indicated ENF68 command response return code.
retcode
The hexadecimal return code from the indicated source.
text
One of the following:
blank
No additional information is provided.
(XCFAS DOES NOT HAVE SAF AUTHORIZATION)
XCFAS does not have SAF authorization to RESET-NORMAL the target system.

System action

When the action was successful, partitioning can complete and message IXC105I will be issued.

When the action was not successful, operator intervention might be required to complete partitioning as indicated by message IXC102A being issued, or another action can be attempted as indicated by message IXC108I being issued. For example, a SYSTEM RESET may be attempted after a FENCE times out.

Operator response

Look for message IXC102A.

System programmer response

If the action was not successful, fix the problem.

Problem determination

When system isolation by a system FENCE is not successful, each system in the sysplex should write a symptom record. A FENCE is likely to time out for the following reasons:
  • System reset, new image loaded, or partition deactivated before fencing completed.
  • No coupling facility was connected and usable by both the system being partitioned and another active system in the sysplex.
If these reasons did not prevent the FENCE from succeeding, provide the symptom record to the IBM® support center for analysis.

There are many factors that could cause a SYSTEM RESET to time out. For return codes from a BCPii callable service, see z/OS MVS Programming: Callable Services for High-Level Languages for more information. For return codes from an ENF 68 command response, see z Systems Application Programming Interfaces for more information.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCS2MON, IXCS2TSK

Routing code

2, 10, Note 13

Descriptor code

4