IXG448I
LOGGER PENDING DUPLEX OPTION CHANGES NOW IN EFFECT FOR LOGSTREAM logstream, CURRENT ATTRIBUTE VALUES: LOGGERDUPLEX({UNCOND | COND}) LOGGERDUPLEX({YES | NO}) DUPLEXMODE([COND | UNCOND | DRXRC])

Explanation

The log stream duplexing options that were pending from the last IXGINVNT REQUEST=UPDATE,TYPE=LOGSTREAM or IXCMIAPU DATA TYPE(LOGR) UPDATE LOGSTREAM requests have been applied and are now in effect for the log stream definition. See Updating a Log Stream's Attribute in z/OS MVS Setting Up a Sysplex for more information about how system logger handles update requests for log stream duplexing options.

In the message text:
logstream
is the name of the log stream.

System action

System logger will attempt to make use of the desired log data duplexing options for the log stream.

Operator response

None.

System programmer response

Check to ensure the desired log stream duplexing options are being used for the log stream. The DISPLAY LOGGER,C,LSN=logstream,Detail command reveals the duplexing methods being used for the log stream. Even though this message says certain duplexing options are in effect, system logger might not be able to use them.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

MANY

Routing code

10

Descriptor code

12