Logger z/OS® IBM zAware (ZAI) log stream client was disconnected from the IBM zAware server because of the quiesce type reason.
System logger has stopped communication between the identified z/OS IBM zAware log stream client and the IBM zAware server for the noted reason.
OMVS ABEND conditions indicating "COMPON=BPX,COMPID=SCPX1..." might occur as part of system logger terminating the socket communications with the IBM zAware server.
Notify the System Programmer.
Verify that the z/OS IBM zAware log stream client is acceptable to be disconnected (quiesced). If it is intended and expected to be connected, then check for related messages IXG384I, IXG371E and/or IXG372I and make any necessary corrections. Also, check on the IBM zAware server level and location to be certain it is installed and running where expected.
Then take action to get the z/OS IBM zAware log stream client connected, for example, see command SETLOGR FORCE,ZAICONNECT,LSN=logstream.