Start of change
IXG286I
LOGGER IS RUNNING IN A DIMINISHED CAPACITY DUE TO A LOSS OF OFFLOAD DATA SET MANAGEMENT SUBTASKS FOR: lstype LOGSTREAMS

Explanation

The system logger component responsible for offload data set management for lstype logstreams has lost multiple logstream resource subtasks.

In the message text:
lstype
One of the following:
DASDONLY
The failed tasks handled DASDONLY logstream requests.
CF STRUCTURE
The failed tasks handled CF structure based logstream requests.

System action

System logger will redistribute offload data set allocations among the remaining lstype logstream resource subtasks. However, related workload (such as offload related data set allocations and deletions) may run in a diminished capacity for lstype logstreams.

Operator response

None.

System programmer response

Consider scheduling a planned outage to restart the IXGLOGR address space. Further loss of logstream resource subtasks can lead to offload failures for lstype logstreams. Message IXG287E or IXG288E might be issued to describe further problems.
Note: Restarting the IXGLOGR address space will impact any executing system logger applications. See Restarting the system logger address space in z/OS MVS Diagnosis: Reference for information on stopping and restarting the IXGLOGR address space. In addition, look for related error messages and any dumps created by system logger, then contact the IBM® Support Center.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGLRTSK

Routing code

2

Descriptor code

4

End of change