IXG102I
SYSTEM sysname FAILED WHILE STRUCTURE strname WAS BEING REBUILT. THE REBUILD WILL CONTINUE BECAUSE THE LOG STREAM DATA IS DEEMED RECOVERABLE.

Explanation

A system failure was detected during structure rebuild processing. Because all log streams using the old structure instance on the failed system are also using staging data sets, system logger has determined that the rebuild can continue.

In the message text:

sysname
The name of the failing system
strname
The name of the structure in the rebuild operation

System action

The structure rebuild continues. Logger will attempt to recover the failing system's log stream data from its staging data sets when the rebuild completes.

Operator response

None.

System programmer response

None.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGC4STE

Routing code

2, 10

Descriptor code

4