Explanation
The maintenance mode state of the coupling facility
was changed. When a coupling facility is in maintenance mode, it
is not eligible for structure allocation purposes. Furthermore,
the coupling facility in maintenance mode is considered an undesirable
location for the structure instances that it already contains, so
that a rebuild or REALLOCATE process will tend to remove those structures
from the coupling facility.
In the message text:
- STARTED
- Maintenance mode has started for the coupling facility. The coupling
facility is now in maintenance mode.
- STOPPED
- Maintenance mode has stopped for the coupling facility. The coupling
facility is now out of maintenance mode.
- type
- Node type (see ndetype in IXLYNDE).
- mfg
- Node manufacturer ID (see ndemfg in IXLYNDE).
- plant
- Node manufacturer plant ID (see ndeplant in IXLYNDE).
- sequence
- Node sequence number (see ndesequence in IXLYNDE).
- patition
- Node LPAR partition number (see ndepartition in IXLYNDE).
- side
- The node PP/SI mode indicator and configuration code from the
IXLYNDE are used to determine the value for side. It can be one of
the following values:
- SIDE: 0
- The coupling facility is on SIDE 0 of a partitionable CPC.
- SIDE: 1
- The coupling facility is on SIDE 1 of a partitionable CPC.
- &BLANK
- The coupling facility is in a non-partitionable CPC.
- cpcid
- Node Central Processor Complex (CPC) ID (see ndecpcid in IXLYNDE).
- cfname
- Name of coupling facility from the CFRM active policy.
System action
System processing continues.
Operator response
System programmer response
Source
Cross System Coupling Facility (SCXCF)
Module
Routing code
Descriptor code