IXC569I
MAINTENANCE MODE STARTED | STOPPED FOR COUPLING FACILITY type.mfg.plant.sequence PARTITION partition side CPCID cpcid NAMED cfname

Explanation

The maintenance mode state of the coupling facility was changed. When a coupling facility is in maintenance mode, it is not eligible for structure allocation purposes. Furthermore, the coupling facility in maintenance mode is considered an undesirable location for the structure instances that it already contains, so that a rebuild or REALLOCATE process will tend to remove those structures from the coupling facility.

In the message text:

STARTED
Maintenance mode has started for the coupling facility. The coupling facility is now in maintenance mode.
STOPPED
Maintenance mode has stopped for the coupling facility. The coupling facility is now out of maintenance mode.
type
Node type (see ndetype in IXLYNDE).
mfg
Node manufacturer ID (see ndemfg in IXLYNDE).
plant
Node manufacturer plant ID (see ndeplant in IXLYNDE).
sequence
Node sequence number (see ndesequence in IXLYNDE).
patition
Node LPAR partition number (see ndepartition in IXLYNDE).
side
The node PP/SI mode indicator and configuration code from the IXLYNDE are used to determine the value for side. It can be one of the following values:
SIDE: 0
The coupling facility is on SIDE 0 of a partitionable CPC.
SIDE: 1
The coupling facility is on SIDE 1 of a partitionable CPC.
&BLANK
The coupling facility is in a non-partitionable CPC.
cpcid
Node Central Processor Complex (CPC) ID (see ndecpcid in IXLYNDE).
cfname
Name of coupling facility from the CFRM active policy.

System action

System processing continues.

Operator response

Not applicable.

System programmer response

Not applicable.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCL2MON

Routing code

2, 10

Descriptor code

4