The LOGR couple data set is not useable on this system because this system is not at the minimum release level required to use the couple data set.
Processing continues. Messages IXC255I and IXC250I are also issued, and they identify the name of the LOGR couple data set being rejected because of the data set consistency checking on this system. If the rejection of the couple data set causes this system to not have access to a primary LOGR couple data set, then message IXG054A will be issued requesting that a LOGR couple data set be made available. Until a primary LOGR couple data set is made available to this system, no logger functions can be exploited by the system, such as updating logger inventory (policy) information or connecting to any log streams.
Notify the system programmer.
If this release level system needs to be brought into the sysplex, see z/OS MVS Setting Up a Sysplex for information about formatting the LOGR couple data set and making it available to the sysplex, in addition to guidance on handling LOGR couple data set format levels and required release levels. If it is intended to use these LOGR couple data set(s) formatted at a higher level than this system can use, then re-IPL this system at the appropriate release level.
None.
None.
System logger (SCLOG)
IXGINVF
1,2,10
12