IXG214I
SYSTEM LOGGER LOGSTREAM DATA DUPLEXING FOR LOGSTREAM logstream IS BEING DONE IN duplexmode text

Explanation

A failure might prevent system logger from using the preferred duplex mode for log stream logstream based on the log stream definition and on the failure dependency of the log stream coupling facility list structure.

This might have been caused by an attempt to offload coupling facility resident data to DASD or an attempt to delete or allocate a staging dataset during the commit phase of a structure rebuild.

In the message text:
logstream
The name of the log stream that the request failed for.
duplexmode
One of the following:
STAGING DATA SETS
System logger is using staging data sets to duplex coupling facility resident log data despite the fact that local buffers may be used based on the failure dependency of the coupling facility that the log stream data resides in.
LOCAL BUFFERS
System logger is using local buffers to duplex coupling facility resident log data despite the fact that Staging Data Sets may be used based on the failure dependency of the coupling facility that the log stream data resides in.
text
One of the following:
STAGING DATA SETS MAY NOT BE THE PREFERRED MODE OF DUPLEXING
LOCAL BUFFERS MAY NOT BE THE PREFERRED MODE OF DUPLEXING
STAGING DRXRC ALSO BEING USED FOR DISASTER RECOVERY

System action

Duplexing of log stream data for log stream logstream will be done in the mode specified by duplexmode. The additional text might also indicate that DRXRC-type staging data set duplexing for disaster recovery (on a secondary or remote site) log stream duplexing might be in effect along with primary site local buffer duplexing.

Operator response

Not Applicable.

System programmer response

Not Applicable.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGC4RPC, IXGC4CON

Routing code

10

Descriptor code

12