ISG158D
PLEXCFG SYSTEM PARAMETER IS INVALID. REPLY ANY, MULTISYSTEM, MONOPLEX OR XCFLOCAL.

Explanation

The system IPLed with an incorrect PLEXCFG system parameter. Valid specifications for the PLEXCFG system parameter are:
  • ANY
  • MONOPLEX
  • MULTISYSTEM
  • XCFLOCAL
  • Any combination of these parameters

System action

Initialization stops until the operator enters a valid response. If the operator enters an incorrect response, the system issues message ISG158D to prompt the operator for a valid response.

Operator response

Notify the system programmer and choose one of the following replies:
ANY
To IPL the system in any of the modes listed
MONOPLEX
To IPL the system into a one system sysplex
MULTISYSTEM
To IPL this system in a multisystem sysplex
XCFLOCAL
To IPL the system in XCF-local mode

System programmer response

Correct the PLEXCFG parameter in the IEASYSxx parmlib member.

Source

Global resource serialization

Module

ISGNCBIM

Routing code

2,10

Descriptor code

2