ISG080E
AUTO RESTART PROCESSING TERMINATED BY SYSTEM sysname. AN OPERATOR MUST ENTER A VARY-GRS RESTART COMMAND AND MUST RESPOND TO OPERATOR PROMPTS.

Explanation

Automatic rebuilding of the global resource serialization ring ended because some systems did not communicate with sysname. The non-communicating systems may have information about multi-system ENQ/DEQ activity needed to rebuild the global resource serialization ring.

System action

AUTO RESTART processing ends. None of the systems will initiate AUTO RESTART.

Operator response

Enter DISPLAY GRS to determine whether global resource serialization communication links are disabled. Identify the systems that did not communicate. They are indicated by a NO in the COMM column of the display.

An operator on one of the systems should issue a VARY GRS RESTART command to rebuild the ring. This command might produce messages ISG081E and ISG082D. The operator should be prepared to do one of the following:
  • Stop some systems in response to message ISG081E
  • Cancel the VARY GRS RESTART command by responding NO to message ISG082D

Source

Global resource serialization

Module

ISGBRF

Routing code

1,10

Descriptor code

11