The ENQ/DEQ control blocks on the resource queues contained incorrect data. The current ENQ or DEQ request did not complete correctly.
If the system is running in a GRS ring, other systems that try to IPL into the ring may fail with ISG014I JOIN REQUEST FROM SYSTEM sysname REJECTED - GLOBAL RESOURCE QUEUES WERE DAMAGED. Systems that try to restart after a global resource serialization ring disruption may fail with a wait state X'0A3' reason code X'70'.
The system repairs the resource queues and might, in the process, delete one or more control blocks.
If the task that encountered the error was processing an ENQ request, the system ends the task with abend code X'738'. If the task was processing a DEQ request, the system ends the task with abend code X'730'.
Any subsequent tasks that issue ENQ requests for resources associated with the damaged control blocks will end with abend code X'838'.
The system processes subsequent DEQ requests.
The system writes a logrec data set error record.
See the operator response for abend code X'730', X'738', or X'838'.
See the system programmer response for abend code X'730', X'738', or X'838'.
Global resource serialization
ISGCMDR, ISGGADMN, ISGRVER
1,10
11