Explanation
text is one of the following:
TOLINT
KEYWORD VALUE INVALID, TOLINT KEYWORD IGNORED
ACCELSYS KEYWORD
VALUE INVALID
REJOIN(YES) NOT ALLOWED WITH RESTART(NO), REJOIN(YES)
IGNORED
SYNCHRES KEYWORD VALUE INVALID, SYNCHRES KEYWORD IGNORED
GRSQ
KEYWORD VALUE INVALID, GRSQ KEYWORD IGNORED
ENQMAXA KEYWORD
VALUE NOT VALID, ENQMAXA KEYWORD IGNORED
ENQMAXU KEYWORD VALUE
NOT VALID, ENQMAXU KEYWORD IGNORED
MONITOR KEYWORD
VALUE NOT VALID, MONITOR KEYWORD IGNORED
During initialization,
global resource serialization found a syntax error in parmlib member
GRSCNFxx.
In the message text:
- xx
- The suffix of the GRSCNFxx parmlib member.
- nnnnnn
- The number of the record containing the syntax error.
- TOLINT KEYWORD INVALID, TOLINT KEYWORD IGNORED
- The value specified for the TOLINT keyword is incorrect. The TOLINT
value, specified in seconds, must be greater than 0 and less than
86000 (24 hours).
- ACCELSYS KEYWORD VALUE INVALID
- The value specified for the ACCELSYS keyword is incorrect. The
ACCELSYS value must be greater than 1 and less than 100.
- REJOIN(YES) NOT ALLOWED WITH RESTART(NO), REJOIN(YES) IGNORED
- REJOIN(YES) and RESTART(NO) are mutually incompatible and cannot
be used in the same GRSCNFxx parmlib member.
- GRSQ KEYWORD VALUE INVALID, GRSQ KEYWORD IGNORED
- GRSQ must be CONTENTION, LOCAL, or ALL. The default of ALL will
be used.
- ENQMAXA KEYWORD VALUE NOT VALID, ENQMAXA KEYWORD IGNORED
- ENQMAXA must be in the range of 250000 to 99999999.
- ENQMAXU KEYWORD VALUE NOT VALID, ENQMAXU KEYWORD IGNORED
- ENQMAXU must be in the range of 16384 to 99999999.
- AUTHQLVL KEYWORD VALUE NOT VALID, AUTHQLVL KEYWORD IGNORED
- AUTHQLVL must be a decimal value of 1 or 2.
- MONITOR KEYWORD VALUE NOT VALID, MONITOR KEYWORD IGNORED
- MONITOR must be YES or NO.
System action
The system rejects the incorrect keyword or specification
and initialization continues.
If the TOLINT keyword is incorrect,
the system uses the default values set by either the system or the
installation. It may take the system longer to detect an overdue ring-processing
system authority (RSA) message.
If the ACCELSYS keyword is incorrect,
the system issues messages ISG044I, ISG007I, and ISG009D.
System programmer response
Do the following:
- If the TOLINT keyword is incorrect, do one of the following:
- Correct the error in GRSCNFxx and reIPL the system.
- Remove the TOLINT keyword from GRSCNFxx if it is not needed and
then reIPL the system.
- If the ACCELSYS keyword is incorrect, do one of the following:
- Correct the error in GRSCNFxx and reIPL the system.
- ReIPL the system using a different parmlib member.
- Remove the ACCELSYS keyword from the GRSCNFxx parmlib member if
you want the system to use the default value. Then reIPL the system.
- If you do not want to reIPL the system, have the operator reply NONE to
message ISG009D.
Source
Global resource serialization
Module
Routing code
Descriptor code