Explanation
text is one of the following:
- VALUE NEAR COLUMN nn NOT WITHIN LIMITS. TEXT
FOLLOWS: text
- NEAR COLUMN nn FIRST VALUE EXCEEDS SECOND.
TEXT FOLLOWS: text
- EXPLICIT VALUE REQUIRED NEAR COLUMN nn. TEXT
FOLLOWS: text
The system found an incorrect OPT parameter in the IEAOPTxx
parmlib member.
In the message text:
- IEAOPTxx
- The parmlib member, where xx is the suffix
of the member.
- VALUE NEAR COLUMN nn NOT WITHIN LIMITS.
TEXT FOLLOWS: text
- The value specified for one of the parameters is outside the allowable
range.
In the message text:
- nn
- The column number.
- text
- The text containing the error.
- NEAR COLUMN nn FIRST VALUE EXCEEDS SECOND.
TEXT FOLLOWS: text
- The first value of a parameter with a pair of values must be less
than or equal to the second value of the pair. The first value is
the low threshold and the second value is the high threshold.
In
the message text:
- nn
- The column number.
- text
- The text containing the error.
- EXPLICIT VALUE REQUIRED NEAR COLUMN nn.
TEXT FOLLOWS: text
- A parameter that requires a pair of values must include both values.
In
the message text:
- nn
- The column number.
- text
- The text containing the error.
System action
The system rejects the OPT parameter and continues
syntax checking. If a parameter with multiple subparameters is in
error, an error message may appear for each subparameter. Syntax checking
continues and may produce additional error messages. The system continues
processing using the existing OPT parameter values.
System programmer response
Correct the error in the IEAOPTxx
parmlib member.
Source
System resources manager (SRM)
Module
Routing code
Descriptor code