IGW01513T
RECFM INCOMPATIBLE — INPUT RECFM = iii OUTPUT RECFM = ooo

Explanation

The record format (RECFM) of the output data set is not compatible with the record format of the input data set. FAMS cannot copy from either a fixed length record format to a variable length record format or to the opposite. Additionally, undefined record format data sets can only be copied to data sets with that same record format.

In the message text:
iii
The record format of the input data set.
ooo
The record format of the output data set.

System action

The system ends processing of the current invocation.

Operator response

Invoke FAMS with compatible record format combination.

Programmer response

Correct the conflicting RECFM specification on the output data set.

Source

DFSMSdfp and File and Attribute Management Services (FAMS).

Routing code

11

Descriptor code

6