IGW322I
SMSVSAM REBUILD PROCESSING HAS BEEN STOPPED FOR LOCK STRUCTURE lockstructurename BECAUSE
{CONNECTIVITY LOST TO THE NEW LOCK STRUCTURE
| CONNECTION TO THE NEW LOCK STRUCTURE FAILED
| OF AN ERROR CONNECTING TO THE NEW LOCK STRUCTURE}

Explanation

The VSAM RLS lock structure rebuild process has lost connectivity to the new lock structure.

In the message text:
lockstructurename
The name of the DFSMS coupling facility lock structure.

System action

If connectivity to the old lock structure is still available, the rebuild process should revert to using the old lock structure.

Operator response

Restore connectivity to the appropriate new lock structure.

System programmer response

Change CFRM policies to ensure that all systems running VSAM RLS always have connectivity to their target coupling facilities.

Source

DFSMSdfp

Module

IGWLNI15

Routing code

2, 10

Descriptor code

4